Commissioning Test
Step-5: Tx Output Power ON
Step-6: Monitoring RSL on MON Connector
Step-7: Catching RSL from Far-end Site
3-8
Click Test & Diagnostic > Control
Click Release button and Tx-OFF turned to Tx-ON.
TX output power is transmitted.
Connect monitoring cable below with MON connector
Confirm received signal level (RSL) using DC volt meter.
Note: Monitoring DC voltage is 0 to +3.3 V depending on path length and
monitoring voltage is not absolute value, but relative value.
Verify that remote Tx power is operational and remote antenna is fixed.
Rotate slowly the antenna in the azimuth direction (horizontal) and find
the maximum RSL voltage.
Rotate slowly the antenna in the elevation direction (vertical) until the
RSL voltage is peak voltage and record the measured voltage.
Repeat above procedure for three times and catch the peak RSL.
Also repeat same procedure in the far-end station
Note: Half antenna beam bandwidth is approx.. 0.6 degree for 1-feet
antenna and 1.0 degree for 2-feet antenna.