.......................................................................................1
................................................................................................1
3-1 Unpacking and Checking..........................................................................1
3-2 Installing Components..............................................................................1
3-3 Leveling the Scale....................................................................................1
4-1 Specifications & General Features .............................................................2
4-2 Front Panel ...........................................................................................3
4-2-1 Display ...................................................................... ........................3
4-2-2 Keyboard.............................................................................................4
4-3 Power Supply...........................................................................................5
5-1 Function Setting......................................................................................5
5-2 Parameters.............................................................................................6
7-1 Weighing...............................................................................................9
7-3-1 Upper & Lower Weight Limit Checking .....................................................10
7-3-2 Upper & Lower Quantity Limit Checking ....................................................11
7-4-2 Sample Counting and ACAL...................................................................13
7-6 Initialization of the Scale to Printer (Optional)................................................14
7-7.The Control from PC to Scale (Optional)......................................................15
8-1 RS-232 Connector..................................................................................15
Appendix 1: Printing format
Content
......................................................8
................................................15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CYD-C8+-3K and is the answer not in the manual?

Questions and answers

Summary of Contents for Hengx CYD-C8+-3K

  • Page 1: Table Of Contents

    Content 1. Introduction …………………………………………………………………….….….1 2. Precaution ……………………………………………………........1 3. Before Using the Product 3-1 Unpacking and Checking………………………………………………….……….…...1 3-2 Installing Components.……………………………………..……………………….…..1 3-3 Leveling the Scale………………………………………..…………………….…..1 4. Product Introduction 4-1 Specifications & General Features ………………………………………….…………2 4-2 Front Panel …………………………………………………………………….…………3 4-2-1 Display …….……………………………………………………… ………….……..3 4-2-2 Keyboard…………………………………………………………………….………..4 4-3 Power Supply………………………………………………………..…….…….…….5 5.
  • Page 2: Introduction

    1. Introduction Thank you for choosing purchase a CYD-C8+ counting scale. This scale has the excellent performance and splendid properties under severe quality management. It is recommended to read this manual in full before using it for good function application. 2.
  • Page 3: Product Introduction

    ④ Plastic weighing pan ⑤ Stainless Steel weighing pan ⑥ On/Off switch ⑦ Transport protection screws ⑧ Power socket 4-1 Specifications & General Features Specifications Model CYD-C8+-3K CYD-C8+-6K CYD-C8+-15K CYD-C8+-30K Capacity(kg) Weighing units Kg/g/lb Display LCD backlit displays (6/5/6 Digits) Pan size 294 x 228 x 13.5mm...
  • Page 4: Front Panel

    General Features · Resolution up to 1/15000 · Tare, Preset Tare, auto zero tracking · Single point and linear calibration available · HI/OK/LO quantity checking function · Weighing platter easy to disassemble with dust proof PVC cover · Low battery and charging status indication ·...
  • Page 5: Keyboard

    calculated unit weight is lower than 4/5 of scale division or the quantity of sample is less than 10 pieces. 13) “UNIT WEIGHT” Unit Weight Window --Displays the average unit weight value, or number of weighing. 14) “TOTAL COUNT” Total count window –Displays the calculated number of pieces on the weighing pan, or accumulated piece count value.
  • Page 6: Power Supply

    setting. Make the blinking spot shift leftwards when inputting the figures. key Press the key to print when printing manually is selected. Set the LO PRINT/LO value. Enable the blinking figure decrease one when inputting the figures. TARE/ key Input the weight of the object on the weighing pan as a Tare value ; Inputs the indicated value entered via the numeric keys as a pre-set Tare value ;...
  • Page 7: Parameters

    5) Press key to save after changing and return to parameters choosing. While M+/SAVE Press key to return without saving. ZERO/ESC 6) Press key again to return to weighing mode. ZERO/ESC Note: In the parameter setting mode, press the numeric key to choose the parameter directly.
  • Page 8 and the stable symbol appears. Off: it starts checking weight once the weight and quantity are within the checking range SET06 beep setting: Hi,ok ,Lo,out,no.beep Hi: There will be a warning sound when the material quantity is more than the upper limit, and the weight of the material is more than 20 divisions Ok: There will be a warning sound when the quantity of the articles is between the upper and lower limit (including the upper and lower limits).
  • Page 9: Single And Multi-Point Calibration

    SET09 printing modes setting: key,stable,contin contin:Printing continually stable:Printing automatically when get a stable weight (more than 20d) key:Printing by pressing keys SET10 printing format setting: prt01~prt03 Use the numeric key to set the format directly. SET11 filtering setting: 1,2,3,4 Set the filtering level in which the stable indication turns on .The higher the setting, the slower stabilization time.
  • Page 10: Operation

    1. Press and hold while powering on. TARE/ Do not release it till the window displays “ CAL” 2. With no load on the weighing pan, press to start zero point calibration. TARE/ 3. Wait till the window displays the first calibration value. Note: The first calibration value is default.
  • Page 11: Checking Function

    into memory. 1) Under the weighing mode, put the container on the scale. Press the key to complete tare action. TARE symbol appears and the window displays as shown on the right 2) Put the item into the container. Then the window displays the net weight. 3)...
  • Page 12: Upper & Lower Quantity Limit Checking

    Press key TARE/ to shift and key to modify the value M-/HI PRINT/LO (or via numeric keys) 3) Press key to start or close weighing checking G N/SET 4) Press key to confirm and save. Press key to return to weighing M+/SAVE ZERO/ESC mode without saving.
  • Page 13: Basic Counting

    to modify the value (or via numeric keys) 3) Press key to start or close weighing checking G N/SET 4) Press key to confirm and save. Press key to return to weighing M+/SAVE ZERO/ESC mode without saving. the sample on the weighing pan. HI indication appears, when the item on the weighing pan is greater than the upper limit OK indication appears, when the item on the weighing pan is between upper and lower limits.
  • Page 14: Sample Counting And Acal

    Unit weight Calling-out 1) Press key. The window displays as shown on the right UWS/ITEM (Press to clear the value in the unit price screen firstly).. M-/HI 2) Input the number of unit weight. Press key TARE/ to shift and key M-/HI to modify the value (or via numeric keys) PRINT/LO...
  • Page 15: Accumulation, Accumulation Display And Accumulation Clear

    sampling again. → 7-5 Accumulation, Accumulation Display and Accumulation clear Accumulation 1) Enter the indicated unit weight, press key and put first piece of load on the UWS/ITEM weighing pan (or into a tared container). (Refer to 7-4-1 and 7-4-2) 2) Press key , the first accumulation event is displayed momentarily before M+/SAVE...
  • Page 16: Initialization Of The Scale To Printer (Optional)

    7-6 Initialization of the Scale to Printer (Optional) Press key while powering on or long press key in the G N/SET G N/SET Step 1 weighing mode to enter parameter setting. Press key TARE/ to circle SET08 the parameters and select 。...
  • Page 17: Troubleshooting And Error Message

    9. Troubleshooting and Error message Error Problem Solution Message The item on the pan should be within 2% of Exceed the zero range ERR0 full load. Model setting error. Resolution Adjust or reset the capacity first then adjust ERR1 should be within 300-300000 resolution 1.Remove the obstacle article under the pan Initial zero point exceeds 30% of full...
  • Page 18 CK、DMP printing format Prt-01 Prt-02 0.500 kg 10 pcs Prt-03 Prt-03 (printing in English) (CK printing in Chinese) N.W.: N.W.: 0.500 kg 0.500 kg U.W.: U.W.: 0.0500 kg/pcs 0.0500 kg/pcs Total: Total: 10 pcs 10 pcs When the window of unit weight shows , the printing format of accumulation display is as follows (01)
  • Page 19: Appendix 2: Exporting Data To Pc In The Form Of Excel

    Appendix 2:Exporting data to PC in the form of EXCEL Introduction: Connect the scale with PC and set the parameter of external device as “EXCEL” on the scale, then you could export the weighing data to PC in the form of EXCEL. With this function, you could record/accumulate/average/data statistical analysis the testing data, which we could call it as scale-computer data management function.
  • Page 20: Troubleshooting

    3. Test if Serial Keys works well. Open a Text Document, and press the Print buotton on the scale. The Serial Keys works well, if pc exports the weighing data to Text. Export weighing data to Excel 1. Open Excel. 2....
  • Page 21: Appendix 3: U.key Conector

    Appendix 3:U.KEY Connector 一、Introduction Connect the scale with PC and set the parameter of external device as “U.KEY” on the scale, then you could export the weighing data to PC in the form of EXCEL. With this function, you could record/accumulate/average/data statistical analysis the testing data, which we could call it as scale-computer data management function.