1 – INTRODUCTION TAKEDO-3VF V20 is a new type of drive with built-in EMC filter, responding to the European Directives 2004/108/EC (EMC) and 2006/95/EC (Low Voltage Equipment). The inverter can operate only in open loop condition. This manual provides you with the essential information about the connections in the control panel and the inverter operation (use of the keypad, parameter and fault message list).
Page 4
INVERTER V20 400 VOLT (380 – 480V) BRAKING RESISTOR RATED MAXIMUM DIMENSIONS FUSES CURRENT CURRENT CODE WxHxD gG/gL SUPPLIED BY SMS MINIMUM VALUE DIMENSIONS (mm) (Ω Ω Ω Ω ) - (W) RECOMMENDED (Ω Ω Ω Ω ) WxDxH (mm) 302.V6.V20CP0009-4 175x275x140 – 500W 200x35x30 Ω...
4 – CONTROL CIRCUITS Number Meaning Control Terminals A-20 STO Terminals Relay Terminals Option Board Terminals STO Jumpers DIP Switches: in position 0, the common of the digital inputs (8-10 e 14-16) is connected to the ground (default position); in position 1, the common above is isolated from ground. AI1 analogue input operating mode;...
5 – APPLICATION DRAWING 5.1 – WITHOUT ENABLE LOGIC TAKEDO - 3VF V20 USER MANUAL Release 1 date 15-04-2013...
Page 7
5.2 – WITH ENABLE LOGIC AND BRAKE SWITCH CONTROL TAKEDO - 3VF V20 USER MANUAL Release 1 date 15-04-2013...
Page 8
6 – NXOPTB5 EXPANDER BOARD (OPTION) The NXOPTB5 board allows you to add N° 3 RELAY OUTPUTS. Terminals Function DEFAULT Setting (*) Contact Technical Information 22 - 23 RO1 - P6.10 = 4 CONTACTORS N.O. Contact Switching capacity: 24VDC/8A 25 - 26 RO2 - P6.11 = 4 250VAC/8A...
Page 9
7 – KEYPAD AND PROGRAMMING The control keypad is the interface between the TAKEDO-3VF V20 and the user. With the keypad it’s possible to check the status of the motor and the inverter, and to set the drive parameters. The BUTTON section is shown in the following picture:...
7.1 – MENU STRUCTURE The data on the control keypad are arranged in menus: • Use the UP and DOWN arrows to move between the menus. Enter the group/item by pressing the OK button and return to the former level by pressing the •...
9 – PARAMETER MENU (Default Values for 400V series) Par. Description Unit Default Value 1 – BASIC PARAMETERS P1.1 Current limit 1,8 x Inv P1.2 Motor nominal voltage P1.3 Motor nominal frequency P1.4 Motor nominal speed 1380 P1.5 Motor nominal current 0,8 x Inv P1.6 Motor Cos Phi...
Eliminate the malfunctioning by delaying the contactors opening. If you can’t do this (for example, in lifts with manual doors, where people opens the car door while car is stopping, set parameter P2.15 to 1. If the alarm still occurs, please contact SMS. TAKEDO - 3VF V20 USER MANUAL Release 1 date 15-04-2013...
Page 14
11 – ADJUSTMENTS P2.3 SPEED P2.12 P2.12 P2.12 P2.12 P3.4 CURVE P2.13 P2.4 P2.2 P2.5 P2.6 P3.1 COMMAND (8 or 9) HIGH SPEED COMMAND (14) LOW SPEED COMMAND (9) P2.14 SMOOTH START DC BRAKING TIME AT START P3.2 DC BRAKING DC BRAKING TIME AT CURRENT STOP...
Page 15
If the lift system doesn’t work as expected, contact the SMS Technical Support. high speed.
Page 16
(high, low, inspection, etc.). For further information and advice contact: SMS SISTEMI e MICROSISTEMI s.r.l. (Gruppo SASSI HOLDING) Cap. Soc. 260.000 i.v. Via Guido Rossa, 46/48/50 40056 Crespellano BO R.E.A 272354 CF - Reg.
Need help?