Download Print this page

Miele G 8066 Installations Plan page 9

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
Cold water or
Hot water
Waste water
External
dispensing
(optional)
Installation plan G 8066
Status: 23.06.2014
3. Voltage (standard version)
Rated load
Fuse rating
Connection cable, min. gauge
Connection cable length (H05(07)RN-F) without
plug
Voltage
Rated load
Fuse rating
Connection cable, min. gauge
Connection cable length (H05(07)RN-F) without
plug
4. Voltage (standard version)
Rated load
Fuse rating
Connection cable, min. gauge
Length of connection cable (SOW-A) with plug
L15-20 Twist Lock
Voltage
Rated load
Fuse rating
Connection cable, min. gauge
Length of connection cable (SOW-A) with plug
L6-30 Twist Lock
It is always recommended to make electrical
connection via a plug and socket so that electrical
safety checks, e.g. during repair or service work, can
be carried out easily. The socket must be accessible
after machine installation.
A fixed electrical connection is possible via an on-site
main switch providing complete isolation from the
mains for all poles. The contact gap must be at least
3 mm.
In order to increase safety, the installation of an earth
leakage circuit breaker is recommended. If
necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all
appropriate national and local regulations.
Maximum temperature
Max. water hardness
G 8066
G 8066 WES (with water softener)
Minimum flow pressure
Maximum pressure
Flow rate
On-site threaded union
Length of connection hose (included)
DVGW certified
Connection to a drinking water supply is permissible
without an additional non-return device.
Drain hose (internal dia. x wall thickness x length)
Max. drain pump head height from base of machine
Max. drain pump head height from base of machine
Transient max. flow rate
On-site hose sleeve for drain hose (outer dia. x
length)
Dispenser unit (DOS G 60 or C 60) connection on
rear panel
V/Hz
3N AC 400/50
kW
10.5
A
3 x 16
mm²
5 x 2.5
m
1.5
V/Hz
AC 230/50
kW
7.0
A
1 x 30
mm²
3 x 4.0
m
1.5
V/Hz
3 AC 208/60
kW
6.2
A
3 x 20
mm²
4 x AWG12
m
2.2
V/Hz
AC 208/60
kW
6.2
A
2 x 30
mm²
3 x AWG10
m
1.8
°C
65
°dH
4
°dH
30
kPa
250
kPa
1000
l/min
4.1
Inch
¾ external
(USA: 11.5 NH)
mm
1500
mm
22 x 6 x 1500
m
0.55
m
1.0
l/min
50
mm
22 x 30
Page 6