Setting The Probe's Ip Address - Network Instruments GigaStor User Manual

Hide thumbs Also See for GigaStor:
Table of Contents

Advertisement

Caution!
When transporting the hard drive, always use the original packaging in which the hard drive was
delivered to you, and avoid exposing the hard drive to extreme changes in temperature to minimize the risk of
condensation. Each drive for the GigaStor is packed in shock-resistant boxes.
Never drop the unit. Handle it with care.
Never place the hard drive in the vicinity of equipment giving off strong magnetic fields, such as CRT
monitors, televisions, or loudspeakers.
Always use an anti-static mat and wrist strap when handling the hard drive. Hold the hard drive by the
base and never touch the components on the circuit board assembly.
If the temperature difference between the storage location and installation location exceeds 50°F/10°C,
for temperature acclimation purposes, leave the hard drive in the new location over night (or at least
two hours) before turning it on.

Setting the probe's IP address

It is unlikely that the probe's default address will be the one you want to keep for it. Configuring the probe's
IP address allows you to put the probe on your network and to connect to it using an Observer analyzer or
Windows Remote Desktop, both of which can be very useful since most probes are in distant or physically secure
locations.
At this point you have physically installed the hardware and connected all the cables. Now, you must turn on the
probe and configure the software. After this is complete all of your interaction with the probe can now be done
remotely by connecting to the probe using an Observer analyzer or Windows Remote Desktop depending on
what you want to accomplish.
1. Connect a monitor, keyboard, and mouse to the probe and ensure the probe is plugged into a power outlet.
These are only needed temporarily to set the IP address. You can disconnect them when you are finished.
Alternatively, you can use Windows Remote Desktop to connect to the probe to make these changes. The
default IP address is 192.168.1.10.
2. Turn on the system. For some probes, such as the GigaStor Upgradeable 5U, you may need to ensure the
power switch is in the "on" position on the back of the probe. Then on the front of the probe, press the
power button until the system starts to turn on.
3. Log in to the Windows operating system using the Administrator account. The default Administrator
password is admin. After logging in, you may change this. See the Windows documentation, if necessary.
4. Click Start > Control Panel > Network and Internet Connections > Network Connections. Choose Local
Area Connection and right-click and choose Properties.
5. Select Internet Protocol Version 4 (TCP/IPv4).
104 | GigaStor™ (pub. 25.Apr.2014)