We appreciate your purchase of the TAKEX microwave sensor. This sensor will provide long and dependable service when properly
installed. Please read this instruction manual carefully for correct and effective use.
Please note : This sensor is designed to detect intrusion and to initiate an alarm; it is not a burglary or a crime preventing device.
TAKEX is not responsible for damage, injury or loss caused by accident, theft, Acts of God (including inductive
1
by lightnin surges), abuse, misuse, abnormal usage faulty installation or improper maintenance.

PRODUCT DESCRIPTION

This Product consists of a transmitter which sends 24GHz band of microwave and a receiver which receives the beam. It will initiate an alarm
signal when the receiver detects a drop in the beam reception level due to interruption of objects interrupt between the transmitter and receiver.
Compared to a photoelectric beam, the wavelength of microwaves is extremely long, which prevent the sensor from being affected by weather
such as torrential rainfall, snowfall, fog or frost especially during cold winters. Stable detection performance is possible.
Two types of frequencies, MW-100AH and MW-100AL are available.
2

PARTS DESCRIPTION

Transmitter:Transmission LED
Receiver :Alarm LED
Cover
3
CAUTIONS ON INSTALLATION
1) DO'S AND DON'TS
・Do not install the unit at places
where it may be blocked by
obstacles such as trees.
5'
(1.5m)
・Do not install the unit a street side
or in parking lots where many cars
may pass by. Installation must be
at 5ft. (1.5m) away from the
automobiles traf c.
Don't install this unit in location
where it is exposed to direct
sunlight or halogen light. It may
become a cause of malfunction.
Don't install other than
correct direction.
(at slant, at upside down)
Don't operate less than 3.3' (1m) detection
distance between transmitter and receiver
even for operation checking.
MICROWAVE SENSOR
MW-100AL
Instruction Manual
Antenna
View finder
Vertical angle
adjustment screw
Adjustment dial
Monitor jack
(Receiver only)
LED
Response time adjustment
potentiometer
(Receiver only)
・Do not install the unit on
unsteady surfaces.
3.3' (1.0m)
3.3' (1.0m)
・When installing the unit along
the side of a building or fence,
installation must be at least
3.3ft. (1m) away from said
constructions.
Don't face the mirror unit to the
sun directly during installing or
replacing.It may become a cause
of malfunction.
It is buried in snow
Freezing
etc.
3.3' (1m) or less
Optional (BP-100MW)
Adjustment mode
switch
(Receiver only)
Knockout
Tamper switch
Top and bottom
2) Height of installation
Install the unit at a height of 3.3' (1m),
ground to center of microwave sensor,
to detect human being walking or
running through the beam.
φapprox
3.3' to 6.6'
(1 to 2m)
A core detection area is approximately φ2' (0.6m) as indicated
above as A, when the alignment is correctly adjusted. It is
suggested to make at least 3.3' (1m) open space on either side of
detection area to prevent faise alarm.
*Please check the detection area by walking test.
Do not stack the sensors vertically.
3) Check the environment of the installation site
The microwaves are affected by electric waves re ected from
buildings, fences, and or the ground.
The beam reception level of the microwaves depends on how the
unit is installed in the area, especially by the height of installation.
Find the position (height) of the sensor for transmitter and
receiver
respenctively where
the maximum signal
reception level can
be obtained before
the nal.
Note:
Install the sensor at a proper height and position otherwise
detection area could be widened over 6.6' (2m).
This could cause the sensor to detect movements of cars or
vegetations near the area and lead to frequent false alarms.
Accessories
Bracket 2
Tapping screw
Countersunk screw
Pole
cover
A
φapprox 2' (0.6m)
16.5' to 330' (5m to 100m)
(φ4×30mm)6
(M4×20mm)4
3.3'
(1m)

Advertisement

loading

Summary of Contents for Takex MW-100AL

  • Page 1: Product Description

    MW-100AL Instruction Manual We appreciate your purchase of the TAKEX microwave sensor. This sensor will provide long and dependable service when properly installed. Please read this instruction manual carefully for correct and effective use. Please note : This sensor is designed to detect intrusion and to initiate an alarm; it is not a burglary or a crime preventing device.
  • Page 2 INSTALLATION Installation example ●Perimeter protection When two or more sets are used, two frequencies (L and H types) should be used in order Do not install the transmitter and the receiver at a same corner. to avoid cross talk or interference. Refer to the following example. Microwave sensor with the same ●Linear protection (long distance) frequency can be used for this case.
  • Page 3 WIRING Terminal arrangement [Transmitter] [Receiver] ① ① Power 12 to 28V DC Power 12 to 28V DC (non-polarity) ② (non-polarity) ② COM. ③ Alarm output ④ Dry contact relay Form C N.O. N.C. 30V (AC/DC) 0.25A ⑤ ⑥ ⑥ Tamper output Tamper output Dry contact relay output N.C.
  • Page 4: Troubleshooting

    Limited Warranty : TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for tness, are limited in duration to 12 months from original date of shipment.