Unit Specifications - Everlast PowerPlasma 60S Operator's Manual

60-100 amp s series igbt inverter platform plasma cutters
Hide thumbs Also See for PowerPlasma 60S:
Table of Contents

Advertisement

Section 1
Specification
Inverter Type
Minimum/Maximum Rated Output
Start Type
Torch Type
Duty Cycle @ Rated Amps/Volts ( 40° C)
(Output V/A)
OCV (U0)
Voltage Input (U1)
Maximum Inrush Amps (I1MAX)
Maximum Rated Effective Amps (I1EFF)
CNC Port
Air Post Flow Timer
Minimum Air Compressor Requirement
Duty Cycle/ Over Current Protection
Minimum Operating Air Pressure
(Safety Cut-Out Threshold)
Recommended Operating Air Pressure
(Set with Air Flow set to "Constant Flow")
Maximum Permissible Static Air Pressure
(Without air flowing)
Maximum Supplied Air Pressure
(From Compressor/Tank)
Recommended Daily Maximum Average Daily
Cut Thickness (Hand Torch)
Recommended Daily Maximum Average Cut
Thickness (CNC)
Rated Maximum Quality Cut @10-12 IPM
(Steel)
Max Severance Cut @ 3 IPM (Steel )
Minimum Water Ingress Protection Standard
Efficiency
Cooling Method
Dimensions (approximate)
Weight (Bare Unit)
Decrease maximum cut thickness values for aluminum and stainless by approximately 40%
When evaluating a plasma cutter for daily service, do not consider maximum severance cut values as criteria for routine use! These maximum specifications are intended for occasional
situations that might require such a cut. Plan the unit's daily use around the recommended average cut thickness for best results and speed. This is an industry standard recommendation
and is not unique to Everlast PowerPlasma models. CNC cut thickness is further reduced as it is typically a 100% duty cycle operation which will require a lower maximum amp setting.
Plasma performance specifications are based on reasonable environmental conditions with well maintained units, and cutting with new consumables using optimum air pressure. Actual
performance results may vary in the field due to variable conditions, power supply, air pressure, air quality, consumable wear etc.
Introduction and Specifications
PowerPlasma 60S
IGBT
20 A/88 V - 60 A/108 V
Blow-Back Type
Innotec iPT60
60% @ 60 A/ 104V
100% @ 50 A/ 100 V
240 V
Standard 220/ 240 V;
50/60Hz 1 Ph
41 A @ 240 V
32.4 A @ 240 V
Yes
Adjustable
5.5 CFM @ 90 psi/
30-60 gallon reserve
Yes
35 psi
70-75 psi
85 psi
90 psi
5/8"
3/8"
1"
1 1/4"
IP21S
>85%
Full Time High Velocity Fan
with Tunnel Design
18" H X 10" W X 25" L
55 lbs
10
PowerPlasma 80S
IGBT
20 A/88 V-80 A/112 V
Blow-Back Type
Innotec iPT80
60% @ 80 A/112 V
100% @ 63 A/104 V
240 V
Standard 220/ 240 V;
50/60Hz 1 Ph
58.4 A @ 240 V
45.2 A @ 240 V
Yes
Adjustable
7 CFM @ 90 psi/
30-60 gallon reserve
Yes
35 psi
70-75 psi
85 psi
90 psi
1"
5/8"
1 1/4"
1 7/16"
IP21S
>85%
Full Time High Velocity Fan
Full Time High Velocity Fan
with Tunnel Design
18" H X 10" W X 25" L
55 lbs
PowerPlasma 100S
IGBT
20/88V
Blow-Back Type
Innotec iPT100
60% @ 100 A/ 120V
100% @ 80A/112V
250V
Standard 220/240V;
50/60Hz 1 Ph(3 Ph. Opt)
78A/45A @ 240V 1Ph/3Ph
60/35 @ 220V 1ph/3ph
Yes
Adjustable
8 CFM @ 90 psi/
60 gallon reserve
Yes
35 psi
70-75 psi
85psi
90 psi
1 1/4"
7/8"
1 3/8"
1 5/8"
IP21S
>85%
with Tunnel Design
18" H X 10"W X 25"l
58 lbs
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerplasma 80sPowerplasma 100s