Maretron ACM100 User Manual page 30

Alternating current monitor
Table of Contents

Advertisement

ACM100 User's Manual
Field 1: Line-Line AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the next phase in units of 1 V.
2: Line-Neutral AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the neutral phase in units of 1 V.
3: AC Frequency – This field indicates the frequency of the AC voltage in units of 1/128
Hz.
4: AC RMS Current (not transmitted for the "Bus" AC Source Type) – This field indicates
the current flowing through the specified phase in units of 1 A.
PGN 65030 – Generator Average Basic AC Quantities
The ACM100 uses this PGN to transmit average voltage, frequency, and current information
when the ACM100's AC Device Type is configured to "Generator".
Field 1: Line-Line AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the next phase in units of 1 V.
2: Line-Neutral AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the neutral phase in units of 1 V.
3: AC Frequency – This field indicates the frequency of the AC voltage in units of 1/128
Hz.
4: AC RMS Current (not transmitted for the "Bus" AC Source Type) – This field indicates
the current flowing through the specified phase in units of 1 A.
PGN 65006 – Utility Phase C AC Reactive Power
The ACM100 uses this PGN to transmit reactive power and power factor information for phase
C when the ACM100's AC Device Type is configured to "Utility".
Field 1: Reactive Power – This field indicates the reactive power delivered by the source in
units of 1 VAr.
2: Power Factor – This field indicates the magnitude of the power factor supplied by the
source in units of 1/16384 (dimensionless).
3: Power Factor Lagging – This field indicates whether the specified power factor is
lagging or leading.
PGN 65009 – Utility Phase B AC Reactive Power
The ACM100 uses this PGN to transmit reactive power and power factor information for phase
B when the ACM100's AC Device Type is configured to "Utility".
Field 1: Reactive Power – This field indicates the reactive power delivered by the source in
units of 1 VAr.
2: Power Factor – This field indicates the magnitude of the power factor supplied by the
source in units of 1/16384 (dimensionless).
3: Power Factor Lagging – This field indicates whether the specified power factor is
lagging or leading.
PGN 65012 – Utility Phase A AC Reactive Power
The ACM100 uses this PGN to transmit reactive power and power factor information for phase
A when the ACM100's AC Device Type is configured to "Utility".
Page A4
Appendix A – NMEA 2000 Interfacing
Revision 1.3