ACM100 User's Manual
Electrical
Parameter
Measurement Voltage Range
Measurement Voltage Accuracy
Measurement Current Range
Measurement Current Accuracy
Operating Voltage
Power Consumption
Load Equivalence Number (LEN)
Reverse Battery Protection
Load Dump Protection
Mechanical
Parameter
Size
Weight
Environmental
Parameter
IEC 60945 Classification
Degree of Protection
Operating Temperature
Storage Temperature
Relative Humidity
Vibration
Solar Radiation
Corrosion (Salt Mist)
Electromagnetic Emission
Electromagnetic Immunity
Safety Precautions
Page 18
Value
0-380 VAC
±1%
0-100 A
±1%
9 to 32 Volts
100 mA
2
Yes
Yes
Value
3.50" x 4.20" x 2.03"
(88.9mm x 106.7mm x 51.6mm)
13 oz. (368.5 g)
93%RH @40° per IEC60945-8.2
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Conducted and Radiated Emission per IEC 60945-9
Conducted, Radiated, Supply, and ESD per IEC 60945-10
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Comment
120,120/240,240,208Y,380Y configurations
With included current transducer (0 to 400A
with optional transducer)
With included current transducer
DC Voltage
®
NMEA 2000
Interface
®
NMEA 2000
Spec. (1LEN = 50 mA)
Indefinitely
Energy Rated per SAE J1113
Comment
Including Flanges for Mounting
Value
Exposed
IP64
-25°C to 55°C
-40°C to 70°C
2
per IEC 60945-8.7
Revision 1.3