Maretron ACM100 User Manual page 28

Alternating current monitor
Table of Contents

Advertisement

ACM100 User's Manual
Field 1: Line-Line AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the next phase in units of 1 V.
2: Line-Neutral AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the neutral phase in units of 1 V.
3: AC Frequency – This field indicates the frequency of the AC voltage in units of 1/128
Hz.
4: AC RMS Current (not transmitted for the "Bus" AC Source Type) – This field indicates
the current flowing through the specified phase in units of 1 A.
PGN 65008 – Utility Phase C Basic AC Quantities
The ACM100 uses this PGN to transmit voltage, frequency, and current information for phase C
when the ACM100's AC Device Type is configured to "Utility".
Field 1: Line-Line AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the next phase in units of 1 V.
2: Line-Neutral AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the neutral phase in units of 1 V.
3: AC Frequency – This field indicates the frequency of the AC voltage in units of 1/128
Hz.
4: AC RMS Current (not transmitted for the "Bus" AC Source Type) – This field indicates
the current flowing through the specified phase in units of 1 A.
PGN 65011 – Utility Phase B Basic AC Quantities
The ACM100 uses this PGN to transmit voltage, frequency, and current information for phase B
when the ACM100's AC Device Type is configured to "Utility".
Field 1: Line-Line AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the next phase in units of 1 V.
2: Line-Neutral AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the neutral phase in units of 1 V.
3: AC Frequency – This field indicates the frequency of the AC voltage in units of 1/128
Hz.
4: AC RMS Current (not transmitted for the "Bus" AC Source Type) – This field indicates
the current flowing through the specified phase in units of 1 A.
PGN 65014 – Utility Phase A Basic AC Quantities
The ACM100 uses this PGN to transmit voltage, frequency, and current information for phase A
when the ACM100's AC Device Type is configured to "Utility".
Field 1: Line-Line AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the next phase in units of 1 V.
2: Line-Neutral AC RMS Voltage – This field indicates the AC RMS voltage between this
phase and the neutral phase in units of 1 V.
3: AC Frequency – This field indicates the frequency of the AC voltage in units of 1/128
Hz.
Page A2
Appendix A – NMEA 2000 Interfacing
Revision 1.3