1MRS 751107-MUM
3.2.
Protection Relay
Operator's Manual

Menu chart

The contents of the menu chart depend on the configuration of the relay. However,
the main menu structure is always preserved.
MAIN MENU
GROUP MENU
Measured values
ABB
IL1-A
IL2-A
IL3-A
Protection
Protection
3I2f>
3I>
3I>>
Control
Manual control
Control
General
I<-->O CB1
I<-->O IND1
Cond. monit.
Cond. monit.
3I MCS
CB wear
TCS
Measurements
Measurements
3I
DREC
Io
Power Quality
Power Quality
PQ 3Inf
Tests
Tests
General
Inputs
Outputs
Configuration
Configuration
Analog scales
Alarm LEDs
Communication
Digital Inputs
Fig. 3.2.-1 An example of a menu chart structure
SUBGROUP MENU
Events
25.0
14 Stored
25.0
3I>> : TRIP
25.0
L1 , L2 , L3
Io-A
5.0
3I>> : START
Demand values
L1 , L2 , L3
IL1-A
25.0
3I>> : TRIP
IL2-A
25.0
L1 , L2 , L3
IL3-A
25.0
3I>> : START
etc.
L1 , L2 , L3
3I>>
Actual settings
Setting group 1
Setting group 2
3I>>>
Control setting
Input data
Io>
Output data
Io>>
Recorded data 1
etc.
Recorded data 2
Recorded data 3
I<-->O CB1
Actual setting
Control setting
Input data
Output data
Recorded data 1
I<-->O IND2
I<-->O POS
3I MCS
Control settings
Input data
Output data
etc.
Recorded data1
Recorded data2
Recorded data3
3I
Control setting
Input data
Recorded data 1
etc.
PQ 3Inf
Statistic limits
etc.
Settings
Test mode
= No test
Activate IRF
=Deactivate
Input states
= 001100010
Output states
= 000000
Rated frequency
= 50.00
Select Io
= 1o, 1/5A
IL1 pu-scale
= 500A
Display
etc.
General
Input SWGRP
Input Signals
Meas. devices
Output SWGRP
Output Signals
Output relays
Protected unit
Self-supervision
Time
REX 521
PARAMETER MENU
2002-22-01
08:32:23.100
2002-22-01
15:10:07.100
2002-22-01
15:10:06.100
2002-22-01
15:10:05.100
Operation mode
= Not in use
Start current
= 0.10x In
Operate time
= 0.05s
Time multiplier
= 0.05
Date
2002-22-01
Time
08:32:23.100
Duration
= 0.1s
Fixed pulse
= Variable pulse
Forced pulse
= Forced pulse
Event delay
= 0.200s
etc.
Operation mode
= In use
Current select.
= L1 & L2 & L3
High limit
= 12% ln
etc.
Phase selection
= L1, L2, L3
Demand interval
= 1 min
Threshold select
= Not in use
etc.
Measuring mode
= Not in use
3 sec. values
Act.Meas.mode
= Not in use
10 min. values
Distort. Factor
A:Period info
= TDD
A:Maxim. values
A:Cumulat. prob.
A:Selected harm.
B:Period info
B:Maxim. values
B:Cumul. prob.
B:Selected harm.
Last exceeding
Inputs/Outputs
Jump
etc.
15