AirHarmony-4000 DC Installation Guide
Integrated External Duplexers
Part Number: UGD-D01123
System Release: 15.0
Revision: A
Published: August 2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AirHarmony 4000 DC and is the answer not in the manual?

Questions and answers

Summary of Contents for Airspan AirHarmony 4000 DC

  • Page 1 AirHarmony-4000 DC Installation Guide Integrated External Duplexers Part Number: UGD-D01123 System Release: 15.0 Revision: A Published: August 2016...
  • Page 2 Airspan Networks Ltd. reserves the right, without prior notice or liability, to make changes in equipment design or specifications. Information supplied by Airspan Networks Ltd. is believed in good faith to be accurate and reliable, while every care has been taken in preparing these documents. However, Airspan Networks Ltd. does not make any representations and gives no warranties of whatever nature in respect of these documents, including without limitation, the accuracy or completeness of any information, facts and/or opinions contained therein.
  • Page 3: Table Of Contents

    Maximum Output TX Total Power ..............7 Power Consumption – Supply and Current ................8 Antenna System ........................9 External Antenna ........................9 About This Document ..................10 Purpose ..........................10 Intended Audience ......................10 Document Conventions ....................... 10 UGD-D01080 Airspan Commercial and Internal Use...
  • Page 4 1 Introduction ....................14 1.1 AirHarmony-4000 ......................14 1.2 Deployment ......................... 14 1.3 Related AirHarmony 4000 DC INT EXT Variants ............16 2 Getting Started .................... 17 2.1 Workflow of Installation ....................17 2.2 AirHarmony-4000 DC INT EXT Installation Checklist ........... 18 3 Verifying Prerequisites .................
  • Page 5 Figure 17: AirHarmony being mounted on a Wall ................34 Figure 18: Grounding ..........................35 Figure 19: Gland connector - copper ....................36 Figure 20: Ethernet Cable through connector ..................37 Figure 21: LC duplex cable assembly ....................38 UGD-D01123 Airspan Commercial and Internal Use...
  • Page 6 Table 2: AirHarmony-4000 DC INT EXT ETSI Maximum Output TX Total Power ........7 Table 3: Power Consumption ........................8 Table 4: Typographic Conventions ......................10 Table 5. AirHarmony 4000 DC Integrated External Duplexers Variants ..........16 Table 6. Minimum Hardware Requirements ..................18 Table 7. Parts & Kits ..........................19 Table 8.
  • Page 7: Document Information

    This document details procedures for installing the Ai spa ’s Ai Ha o -4000 DC INT EXT, a Macro- class eNodeB variant and its place in the Airspan product suite. This document is intended for qualified personnel with a working knowledge of LTE.
  • Page 8: Warnings And Cautions

    Failure to do so may void Airspan's product warranty and may expose the end user or the service provider to legal and financial liabilities. Airspan and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas.
  • Page 9: Important Safety Instructions

    Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990). At the end of any Airspan products life cycle, the customer should consult with Airspan to ensure that the product is disposed of in conformance with the relevant regulatory requirements.
  • Page 10: Adherence To European Directive 1999/5/Ec

    Airspan equipment is compliant with CE and R&TTE regulations and can be operated in all EU (European Union) locations listed below:...
  • Page 11: Ul Information

    - The circuit ground must be connected to the same grounding system as the eNodeB. Outdoor Ethernet Cabling - Ethernet cable connected to should be outdoor grade with UV protection. - Use shielded out CAT5e (minimum) cabled terminated with metallic RJ45 connectors. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 12: Declaration Of Conformity

    Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC. Português: Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC. Suomalainen: Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 13: Gps Compliance

    Note: A GPS is recommended for synchronizing between LTE sectors. Note: An optional GPS Lightning/Surge protector is available from Airspan when installing the GPS antenna in a remote location for lightning prone deployments. Maximum Output TX Total Power Table 1: AirHarmony--4000 DC INT EXT FCC Maximum Output TX Total Power...
  • Page 14: Power Consumption - Supply And Current

    Transient Voltage: +150V (ETR283)  The use of other power sources may impair safety AC power feed is also available, using an AC/DC power converter offered by Airspan. Warning: Power provided by PoE outputs (RJ45 ETH1, ETH2) cannot be considered limited power source (LPS) per IEC/UL 60950-1 clause 2.5...
  • Page 15: Antenna System

    Integrated External Duplexers of the AirHarmony-4000 DC INT EXT variant unit. Various antennas are designed specifically for AirHarmony-4000 DC INT EXT deployments; specifications are available from Airspan separately. External Antenna The externally mounted antenna should be a dual slant or cross polarized fixed antenna which is connected via DIN connectors located on the Integrated Duplexers.
  • Page 16: About This Document

    Signifies a hazardous situation—if not avoided—will cause Danger death or serious injury. Describes how to avoid it. Signifies a hazardous situation—if not avoided—can cause Warning death or serious personal injury. Describes how to avoid it. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 17 Signifies a hazardous situation—if not avoided—can void Caution the product warranty, and cause property damage. Describes how to avoid it. Important Provides necessary information to explain a task. Note Provides additional information. Provides helpful hints. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 18: Document Organization

    Provides information that aids users in performing the installation. Abbreviations Lists the abbreviations used in this document and their expansions. Related Reading The following documents contain related information: AirHarmony-4000 Hardware Product Specification Airspan LTE Commissioning Manual UGD-D01123 Airspan Commercial and Internal Use...
  • Page 19: Customer Care Help Desk

    Tel: +1 561 893 8670 SL1 3UF, United Kingdom Tel: +44-1895-467-100 Airspan Encourages Comments Airspan welcomes any feedback and suggestions that help to improve the quality of the documentation. Send your feedback to documentfeedback@airspan.com. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 20: Introduction

    This se tio p o ides a des ipti e o e ie of the Ai spa ’s AirHarmony-4000 with Integrated External Duplexers a Macro-class eNodeB variant and its place in the Airspan product suite. This document is intended for readers with LTE working knowledge.
  • Page 21: Figure 2: Airharmony-4000 Dc Int Ext

    AirHarmony-4000 must be properly grounded (16AWG minimum) according to NEC and other local safety code requirements. Warning: Required - circuit breaker for AC power source -16A for EU installation and 20A for US installation. Minimum – 10A. Figure 2: AirHarmony-4000 DC INT EXT UGD-D01123 Airspan Commercial and Internal Use...
  • Page 22: Related Airharmony 4000 Dc Int Ext Variants

    AirHarmony-4000 DC (Integrated External Duplexers) Installation Guide 1.3 Related AirHarmony 4000 DC INT EXT Variants This document is related to AirHarmony 4000 DC power with integrated external duplexes variants. The following table lists the relevant variants: Table 5. AirHarmony 4000 DC Integrated External Duplexers Variants...
  • Page 23: Getting Started

    2.1 Workflow of Installation The Workflow to install the AirHarmony-4000 DC INT EXT is displayed in the following diagram: Figure 3: Workflow Caution: Antennas must be connected and attached before AirHarmony-4000 DC INT EXT is powered on. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 24: Airharmony-4000 Dc Int Ext Installation Checklist

    Knife For AC cable preparation Small side cutters For AC power cable preparation Wire strippers For AC power cable preparation / ” Socket Wrench For / ” He head (Lag) bolts when wall mounting UGD-D01123 Airspan Commercial and Internal Use...
  • Page 25: Verify The Parts And Kits

     Pole/wall mount bracket AirHarmony HAR40-U-PMK- 903-03-257  Screws for connecting 4000 universal wall & pole the unit mounting kit Optional AC / DC Power Converter – Available from Airspan AC/DC Indoor AC-DC-IDU- 133-00-061 AC/DC Power Converter for power Air4G-W24 AirHarmony-4000 DC converter...
  • Page 26: Power Supply And Current

    AirHarmony-4000 DC INT EXT supports direct connection to AC power source:  Operational Voltage Range: 100VAC~240VAC, 47Hz~63Hz Warning: Power provided by PoE outputs (RJ45 ETH1, ETH2) cannot be considered limited power source (LPS) per IEC/UL 60950-1 clause 2.5 UGD-D01123 Airspan Commercial and Internal Use...
  • Page 27: Table 8. Amperage Draw

    AirHarmony-4000 DC (Integrated External Duplexers) Installation Guide Table 8. Amperage Draw Duplex Tx Power at RF Port (dBm) Maximum Power Consumption (W) TDD-FC1 2 x 43 2 x 43 UGD-D01123 Airspan Commercial and Internal Use...
  • Page 28: Panels

    3.2.4 Panels The following figures display the AirHarmony-4000 DC INT EXT bottom and top panels. The following displays the AirHarmony-4000 DC INT EXT’s otto panel. Figure 4: AirHarmony-4000 DC INT EXT Unit, Bottom panel UGD-D01123 Airspan Commercial and Internal Use...
  • Page 29: Physical Dimensions

    Main Unit (with integrated external duplexers) 27 Kg / 59.52 Lbs. Universal mounting bracket 3 Kg / 6.6 Lbs. 3.2.6 Environmental AirHarmony-4000 DC INT EXT meets the following environmental requirements:  GR-63 Storage and Transportation UGD-D01123 Airspan Commercial and Internal Use...
  • Page 30: Table 10: Airharmony-4000 Environment Compliance

    Rain and dust ingress IP66 protection 70-106 kPa as well as: Operational altitude From -60m to 1800m @ 40C ETSI 300 019 1-4 From 1800m to 4000m @ 30C Solar radiation 1120 W/m ETSI 300 019 1-4 UGD-D01123 Airspan Commercial and Internal Use...
  • Page 31: Installing Airharmony-4000 Dc Int Ext

    4.2 Pole/Wall Mount Assembly Install the AirHarmony-4000 DC INT EXT eNodeB by pole/wall mount. AirHarmony-4000 DC INT EXT is mounted on a pole or wall in close proximity to its external antenna (connectorized variant). UGD-D01123 Airspan Commercial and Internal Use...
  • Page 32: Mounting On A Wooden Pole

    Determine where to position the mounting plate on the pole and mark where to drill for insertion of the 3/8-16 through-bolt. Note: Threaded rod and necessary hardware are not supplied by Airspan and are the responsibility of the installer. UGD-D01123...
  • Page 33: Figure 8: Mounting Plate On Pole

    Insert the clamp bands by passing them through the slots in the mounting plate, in three (3) places. Note: The clamp bands are not supplied by Airspan and are the responsibility of the installer. Clamp bands should not be wider than 15.5 mm in order to fit in the slots on the mounting plate.
  • Page 34: Mounting On A Non-Wooden Pole

    The following images show the pole mount assembly on a non-wooden pole. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below. Figure 10: Pole/Wall mounting plate (w/o bolt) UGD-D01123 Airspan Commercial and Internal Use...
  • Page 35: Mounting On A Wall

    Insert the clamp bands by passing them through the slots in the mounting plate, in four (4) places. Note: The clamp bands are not supplied by Airspan and are the responsibility of the installer. Clamp bands should not be wider than 15.5 mm in order to fit in the slots on the mounting plate.
  • Page 36: Figure 12: Mounting Plate On Wall

    Attach the mounting plate to the wall using Lag bolts (x8 recommended). Note: Lag bolts (x8) and necessary hardware are not supplied by Airspan and are the respo si ilit of the i staller. Re o e ded i i u ”...
  • Page 37: Securing Airharmony-4000 To The Mounting Plate

    (studs) on the top of the mounting plate. Figure 13: Lift unit and fit the slotted holes unto studs on top of mounting plate The following displays a close up of the Pin (stud) alignment. Figure 14: Align Pins UGD-D01123 Airspan Commercial and Internal Use...
  • Page 38: Figure 15: Airharmony Mounted On Wooden Pole

    Once aligned insert the supplied M8x20 Hex head bolt with a split washer and a flat washer into each clinch-nut. Check and tighten all six (6) M8x20 Hex head bolts. The following displays the AirHarmony-4000 mounted on a wooden pole. Figure 15: AirHarmony mounted on Wooden Pole UGD-D01123 Airspan Commercial and Internal Use...
  • Page 39: Figure 16: Airharmony Mounted On Concrete Pole

    AirHarmony-4000 DC (Integrated External Duplexers) Installation Guide The following displays the AirHarmony-4000 mounted on a concrete pole. Figure 16: AirHarmony mounted on Concrete Pole UGD-D01123 Airspan Commercial and Internal Use...
  • Page 40: Figure 17: Airharmony Being Mounted On A Wall

    AirHarmony-4000 DC (Integrated External Duplexers) Installation Guide The following displays the AirHarmony-4000 being mounted on a wall. Figure 17: AirHarmony being mounted on a Wall UGD-D01123 Airspan Commercial and Internal Use...
  • Page 41: Airharmony-4000 Dc Int Ext Connections

    Attach, connect and secure the RF cable between the external antenna and the appropriate RF connection on the top of the Integrated Duplexers. Caution: Antennas must be connected and attached before AirHarmony is powered on. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 42: Weather-Proofing The Antenna Connections

    (CAT5e) cable used by Airspan products. The Ethernet cable is connected using a standard RJ45 connector protected by a harsh environment protective casing. Hardware Requirements The following are the cable and connectors available from Airspan. Table 11: Cable Hardware Airspan Part Number Description...
  • Page 43: Fiber Ethernet (Sfp) Cable Installation

    Note: Airspan recommends using the Finisar - FTLF1318P3BTL 1000BASE-LX which has been tested and approved by Airspan. Available from Airspan if required. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 44: Sfp Cable Connection

    Figure 22: Cable connector hook up to the board connector Verify that the locking latch on the cable connector is engaged on the board connector. Slide the inner housing and ground shield (if present) over the cable and over the molding. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 45: Connecting The Dc Power Cable To Airharmony-4000 Dc Int Ext

    5.5 Connecting the DC Power Cable to AirHarmony-4000 DC INT EXT Danger: Hazardous voltage! Before working, ensure that the power is removed from the power connection cables. When the system is powered on, do not touch the power terminals. UGD-D01123 Airspan Commercial and Internal Use...
  • Page 46: Connecting The Dc Power Cable To Airharmony

    Position the pins correctly, the connector is secured to the unit with a locking ring that is screwed into place. Use firm hand pressure only, the connector has a built in sealing ring. Figure 25: attaching power cable to AirHarmony UGD-D01123 Airspan Commercial and Internal Use...
  • Page 47: Ac/Dc Power Converter - Optional

    The third-party external AC/DC Power Converter is an optional unit that connects to the AirHarmony-4000 DC in the event there is no -48VDC availability at the site. Note: Airspan recommends using the AC/DC Power Converter for the AirHarmony-4000 DC. Available from Airspan if required. Figure 26: Optional AC/DC Converter...
  • Page 48: A Job Sheet

    13 mm wrench Knife pliers Small side cutters Wire strippers Required Ancillary Equipment Laptop PC for initial configuration Cable for temporary connection of the laptop Other installed materials Cable ties Labels (good to have) UGD-D01123 Airspan Commercial and Internal Use...
  • Page 49: B Abbreviations

    De Multiple i g, et … MBSFN Multicast-Broadcast Single Frequency Network is an LTE feature designed to deliver services such as Mobile TV using the LTE infrastructure, and is expected to be a competitor to DVB-H- based TV broadcast UGD-D01123 Airspan Commercial and Internal Use...
  • Page 50 TCP Software Defined Radio Time-Division Duplexing. A transceiver mode where the transmitter and receiver operate on the same carrier frequency User Equipment. The end user in LTE WEEE Waste Electrical and Electronic Equipment UGD-D01123 Airspan Commercial and Internal Use...

Table of Contents