DALI Touch ME7

Pre-set dynamic sequences

When selecting "pre-set dynamic se-
quences" in TW mode user will see three
dynamic white pre-sets:
"daylight", "activate" and "moving".
By pressing the buttons corresponding
pre-set sequences will be selected and
sequence timing screen will appear.
Parameters of dynamic sequence can
be set after selection of the sequence.
Repetition of the sequence can be
enabled or disabled and number of
repetition can be set. The user can
also define whether the light should be
turned off after the end of sequence
or not. The sequence starts after
confirmation by pressing OK button. The
activated sequence is indicated in the
information bar as well as with the play
sign placed on the corresponding pre-
set button. The sequence will be active
until other sequence or scene is set or
manual control is used. In RGB mode
there are eight pre-set options. Timing
settings looks the same as for TW mode.
Activated sequence.