6-2. Outdoor unit
HWS-P805HR-E, P1105HR-E
No.
Component name
Compressor
1
2
Outdoor fan motor (x2)
Reactor (x2)
3
4
4-way valve coil
5
Pulse motor valve (PMV) coil
Compressor case thermostat
6
7
PC board
High pressure sensor
8
2-way valve coil
9
10
High pressure switch
6-3. Hot water cylinder unit
No.
Component name
Hot water cylinder heater
1
Hot water cylinder temperature
2
sensor
(TTW sensor)
Thermal cut-out
3
O ······· Applied
Type name
DA422A3F-26M
ICF-280-A100-1
Output 100 W
CH-44
1.4 mH, 25 A
STF-H01AP1874A1
AC220 - 230 V full-wave rectifier input, alive time 10 sec or less
UKV-A038
DC12 V
US-622KXTMQO-SS
OFF = 125 ± 4 °C, ON = 90 ± 5 °C
MCC-1571
Input 1Ø, AC220 - 230 V ± 10%, 50/60 Hz
NSK-BH042D-430
0 ~ 4.15 MPa
VPV-MOAJ510B0
AC220 - 240 V
ACB-4UB154W
OFF = 4.15 + 0, -0.15 MPa
Model name
1501
2101
3001
Type name
CSH
CSH
CSH
M3-E
M3-E
M3-E
(-UK)
(-UK)
(-UK)
O
O
O
O
O
O
O
O
O
25
Rating
AC230 V 2.7 kW
10 kΩ (25 °C)
Operating temperature
Manual reset 82 °C (+3K/-2K)
Rating