Specifications - Toshiba HWS-P805XWHM3-E Service Manual

Table of Contents

Advertisement

3

Specifications

Unit name
Hydro unit
Outdoor unit
Heating capacity *1 (kW)
Cooling capacity *2 (kW)
Variable range of compressor frequency
Power source
Operation mode
Electric characteristic *1 *2
Outdoor unit
Total
Operating noise sound power level
Hydro unit (dB (A))
Outdoor unit (dB (A))
Coefficient of performance *1 *2
Hydro unit
Outer dimension
Net weight (kg)
Color
Remote controller
Outer dimension *3
Circulation pump
Heat exchanger
Outdoor unit
Outer dimension
Net weight (kg)
Color
Compressor
Fan motor
Refrigerant piping
Connection method
Hydro unit
Outdoor unit
Maximum length (m)
Maximum chargeless length (m)
Maximum height difference (m)
Minimum length (m)
Refrigerant
Refrigerant name
Charge amount (kg)
Water piping
Pipe diameter
Maximum length (m)
Maximum height difference (m)
Maximum working water pressure (kPa) *4
Operating temperature range
Hydro unit (°C) *5 (Cooling / Heating / Hot water)
Outdoor unit (°C) (Cooling / Heating / Hot water)
Operating humidity range
Hydro unit (%)
Outdoor unit (%)
Wiring connection
Power wiring
Connecting line
*1 Heating performance measurement conditions: outside air temperature 7 °C, water supply temperature 30 °C, outlet temperature 35 °C, refrigerant piping length 7.5 m (no height
difference).
*2 Cooling performance measurement conditions: outside air temperature 35 °C, water supply temperature 12 °C, outlet temperature 7 °C, refrigerant piping length 7.5 m (no height
difference).
*3 • The remote controller should be shipped with the hydro unit.
• Use two 1.5-meter wires to connect the hydro unit with the remote controller.
*4 Check the water piping for leakage under the maximum operating pressure.
*5 Do not leave the hydro unit at 5 °C or below.
Hydro unit
Current (A)
Power (kW)
Power factor (%)
Current (A)
Power (kW)
Power factor (%)
Running current (A)
Height (mm)
Width (mm)
Depth (mm)
Height (mm)
Width (mm)
Depth (mm)
Motor output (W)
Flow rate (L/min)
Type
Height (mm)
Width (mm)
Depth (mm)
Motor output (W)
Type
Model
Standard air capacity (m
Motor output (W)
Liquid
Gas
Liquid
Gas
HWS-P805XWHM3-E, P805XWHT6-E, P805XWHT9-E
Heating
0.44
0.06
59.3
7.57
1.62
93
8.01
4.76
22.9
Twin rotary type with DC-inverter variable speed control
3
/min)
None (Need the flow rate 13 /min or more)
3 wires: including earth wire (Outdoor unit)
15
HWS-P805HR-E
8.0
6.0
10 - 70 Hz
Single phase 50 Hz 220-230 V
Cooling
0.44
0.06
59.3
7.39
1.58
93
7.83
41
66
3.66
925
525
355
49
Silky shade (Munsell 1Y8.5/0.5)
120
120
16
125 (MAX)
17.2
Non-self-suction centrifugal pump
Plate-type heat exchange
1340
900
320
92
Silky shade (Munsell 1Y8.5/0.5)
2500
DA422A3F-26M
103.0
100 × 2
Flare connection
Ø9.52
Ø15.9
Ø9.52
Ø15.9
30
30
±30
5
R410A
2.7
R1 1/4
±7
430
5-32 / 5-32 / 5-32
10-43 / -25-25 / -25-43
15-85
15-100
4 wires: including earth wire