Troubleshooting - LG CodePlus OAT100R Installation & Setup Quick Reference

Off air transcoder system
Hide thumbs Also See for CodePlus OAT100R:
Table of Contents

Advertisement

Troubleshooting

This section provides introductory OAT100R installation and setup troubleshooting
information. Refer to the extended Installation & Setup Guide for additional trouble-
shooting information.
Equipment Setup Review
Make sure all connectors and connections are tight and secure on all entertainment
system components.
Check the OAT100R LEDs:
Under standard operating conditions the PWR (Power) LED on the OAT100R front
panel is continuously lit green. If there is a hardware fault, the PWR LED will turn
and stay red. (When power is fi rst applied to the OAT100R, the PWR LED initially
flashes red and then turns green.)
When the OAT100R is booted and operating normally, the STATUS LED is
continuously lit green.
Network Setup
If the network is configured for DHCP but the OAT100R has not been assigned an IP
address, i.e., the Ctrl IP field in the OAT100R System Information display is blank:
1. Check the Control Port connector on the rear panel of the OAT100R. Make sure the
cable connection is tight and secure.
2. Observe the green LED on the Control Port. Once the OAT100R is connected to
the network, the LED will be lit continuously.
3. Contact the network administrator to verify the network status and check that the
DHCP server is working properly.
24
IMPORTANT SAFETY INSTRUCTIONS
(Continued from previous page)
B. Reduced Air Flow
Installation of the equipment in a rack should
be such that the amount of air flow required
for safe operation of the equipment is not
compromised. To ventilate the system nor-
mally and avoid overheating, leave at least
1 inch (2.5 cm) on each side (including top
and bottom) of the OAT100R. Do NOT stack
other equipment on the top of the OAT100R.
C. Circuit Overloading
Consideration should be given to the
connection of the equipment to the supply
circuit and the effect that overloading of the
circuits might have on overcurrent protection
and supply wiring.
D. Reliable Earthing
Maintain reliable earthing of rack-mounted
equipment. Particular attention should be
given to supply connections other than direct
connections to the branch circuit (e.g. use of
power strips).
206-4219
206-4219
E. Mains Outlet Earthing
The apparatus with Class I construction must
be connected to a mains socket outlet with a
protective earthing connection.
OAT100R Installation on a Flat Surface
To install the OAT100R on a level surface (table
top, shelf, etc.):
Install the equipment in an environment
compatible with the maximum operating
ambient temperature (Tma) specifi ed by the
manufacturer (see Specifi cations information
in this document).
Place spacers or rubber feet (not provided) on
the bottom of the OAT100R.
Carefully place the OAT100R on the level
surface.
To ventilate the system normally and avoid
overheating, leave at least 1 inch (2.5 cm) on
each side (including top and bottom) of the
OAT100R. Do NOT stack other equipment on
the top of the OAT100R.