Rear and Front Panel Overviews

OAT100R Rear View
RF -O
U T
RF OUT
RF IN 8
Disconnect Device
The AC mains plug is used
as the disconnect device.
The disconnect device must
remain readily operable.
OAT100R Front View
Ventilation Holes
Air flow must not be obstructed. To
ventilate the system normally and
avoid overheating, leave at least 1
inch (2.5 cm) on each side (including
top and bottom) of the OAT100R. Do
NOT stack other equipment on the
top of the OAT100R.
10
RF -IN
8
RF -IN
7
RF -IN
6
RF -IN
5
RF -IN
4
RF -IN
3
RF -IN
2
RF -IN
1
RF IN 1
FEATURE
& CONTROL
(Ethernet) Ports
AC Power
Cord & Adapter
P W
R
S TA
TU S
POWER LED
STATUS LED
USB Port
Service Port
(Continued from previous page)
Note: If you change the Control Port configuration, you will be prompted to reset the
system. If you intend to modify additional configuration settings during the current
session, you may wait until all changes are complete before you reset the system.
15. Once all physical connections to the OAT100R have been made and the Control Port
IP address has been assigned or configured, you also have the option to complete
the system setup remotely using either the web GUI or the command line interface.
To complete the system setup in the current session (via the Service Port),
continue with step 16.
If you wish to complete the setup remotely, reset the system at this time: At either
the Command > prompt or the Setup Command > prompt, type reset and press
Enter (also confi rm the reset when prompted to do so). When you are ready,
establish remote communication with the OAT100R, and then continue with step 16.
Note that you may use the GUI to perform the confi guration steps, if desired. Refer
to the extended Installation & Setup Guide for further information on establishing
remote communication with the OAT100R and/or for further information on the GUI.
16. (Required only if Pro:Idiom channels are present in the system) Check the Program
PIDs field in the System Information display (if necessary, you can rerun the "info"
command from either the Command > or Setup Command > prompt). If the
default range (0x30 - 0x6f) is not appropriate for this system, set the PIDs as follows:
a) If the Command > prompt is on display, type setup and press Enter to access
the Setup Menu.
b) At the Setup Command > prompt, type pid and press Enter. The system will
display the current (default) PID confi guration, followed by a prompt for the starting
program PID:
Enter the starting program PID [0x30]:
c) Type the new starting program PID in hexadecimal format and then press Enter.
(The system will auto-increment the remaining program PIDs.)
d) The system will display an overview of the new confi guration and prompt for
confi rmation:
Do you want to save the new configuration? [y/n]:
Review the PID confi guration to ensure it is correct, and then type y and press
Enter. The system will confirm your update:
New configuration has been saved.
206-4219
206-4219
System Setup (Cont.)
(Continued on next page)
19