Download Print this page

York YCJD18 Technical Manual page 5

Lx series split-system air conditioners 13 seer – r-410a – 1 phase 1.5 thru 5 nominal tons models: ycjd18 thru 60
Hide thumbs Also See for YCJD18:

Advertisement

COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
MODEL
AHE42D
AHE48D
AHE60D
AHR42C
AHR48D
AHR60D
AHV42D
AHV48D
AHV60D
YCJD42S41S2(H)(E)
AHE48D
AHR48D
AHV48D
AHV60D
YCJD48S41S1(H)(E)
AHE60D
AHR60D
AHV60D
YCJD60S41S1(E)
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings
Johnson Controls Unitary Products
AIR HANDLER
WIDTH
13 SEER AC WITH AIR HANDLERS
24.5
24.5
24.5
21.0
24.5
24.5
24.5
24.5
24.5
AV*48
24.5
AV*60
24.5
MV16C
21.0
MV16C
21.0
MV16C
21.0
MV20D
24.5
MV20D
24.5
MV20D
24.5
MV20D
24.5
MX16C
21.0
MX16C
21.0
MX16C
21.0
MX20D
24.5
MX20D
24.5
MX20D
24.5
MX20D
24.5
24.5
24.5
24.5
24.5
AV*48
24.5
AV*60
24.5
MV16C
21.0
MV16C
21.0
MV20D
24.5
MV20D
24.5
MX16C
21.0
MX20D
24.5
MX20D
24.5
24.5
24.5
24.5
AV*60
24.5
MV20D
24.5
MV20D
24.5
MV20D
24.5
MX20D
24.5
MX20D
24.5
MX20D
24.5
COIL
RATED
1
MODEL
CFM
1385
1385
1390
1485
1320
1350
1385
1300
1340
1385
1360
FC/MC43C
1380
FC/MC48C
1400
FC60C
1400
FC/MC48D
1470
FC/MC60D
1400
FC/MC62D
1400
FC64D
1400
FC/MC43C
1365
FC/MC48C
1390
FC60C
1420
FC/MC48D
1415
FC/MC60D
1470
FC/MC62D
1470
FC64D
1470
1600
1610
1585
1570
1625
1560
FC/MC48C
1600
FC60C
1625
FC/MC48D
1600
FC/MC60D
1600
FC/MC48C
1685
FC/MC48D
1525
FC/MC60D
1585
1835
1870
1635
1730
FC/MC60D
1800
FC/MC62D
1800
FC64D
1855
FC/MC60D
1780
FC/MC62D
1795
FC64D
1795
840569-YTG-B-1012
COOLING
NET MBH
SEER
TOTAL
SENS.
42.0
30.6
14.25
42.0
30.4
14.00
42.0
31.0
14.50
42.0
30.8
13.00
41.0
28.8
13.00
42.0
30.2
13.00
42.0
30.2
13.75
41.5
29.1
14.00
42.0
30.2
14.00
42.0
30.4
14.25
42.0
30.4
14.25
42.0
30.2
14.00
42.0
30.4
13.75
42.0
30.0
13.75
42.0
31.0
14.25
42.0
30.2
14.00
42.0
30.8
14.00
42.0
30.8
14.50
42.0
30.2
14.25
42.0
30.2
14.25
42.0
30.0
14.00
42.0
30.2
14.25
42.0
30.8
14.25
42.0
31.6
14.50
42.0
31.6
14.75
47.0
34.6
13.75
48.0
34.6
13.00
47.5
34.0
13.25
48.0
35.0
13.50
48.0
35.0
13.50
48.0
35.0
13.50
48.0
35.0
13.50
47.5
34.6
13.50
48.0
35.0
13.50
48.0
35.0
13.50
48.5
35.6
13.75
48.0
34.2
14.00
48.5
34.6
14.00
58.5
39.8
13.50
57.0
38.5
13.00
57.0
38.5
13.50
58.0
39.0
13.50
57.0
38.5
13.00
57.0
38.5
13.00
57.0
39.0
13.75
57.5
38.8
13.75
58.0
38.8
14.00
58.5
39.8
14.50
EER
12.00
12.00
12.00
11.00
11.00
11.00
11.75
12.00
12.00
12.00
12.00
12.00
11.75
11.50
12.00
11.75
12.00
12.25
12.00
12.00
12.00
12.00
12.00
12.25
12.50
11.50
11.00
11.50
12.00
12.00
12.00
12.00
11.50
12.00
12.00
11.50
11.75
12.00
11.50
11.00
11.50
11.00
11.00
11.00
11.50
11.50
11.75
12.00
5

Advertisement

loading

This manual is also suitable for:

Ycjd30Ycjd24Ycjd42Ycjd48Ycjd60Ycjd36