Download Print this page
York YCJD18 Technical Manual

York YCJD18 Technical Manual

Lx series split-system air conditioners 13 seer – r-410a – 1 phase 1.5 thru 5 nominal tons models: ycjd18 thru 60
Hide thumbs Also See for YCJD18:

Advertisement

Quick Links

TECHNICAL GUIDE
LX SERIES
SPLIT-SYSTEM AIR CONDITIONERS
13 SEER – R-410A – 1 PHASE
1.5 THRU 5 NOMINAL TONS
MODELS: YCJD18 THRU 60
®
Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at
www.upgnet.com and www.york.com
Additional rating information can be found at:
www.ahridirectory.org
WARRANTY SUMMARY*
Standard 5-Years limited parts warranty.
Standard 10-Years limited compressor warranty.
Extended 10-Years limited parts warranty when product is
registered online within 90 days of purchase for replacement
or closing for new home construction.
*Does not apply to R-22 models, 3-Phase models, or internet sales.
See Limited Warranty certificate in User's Information Manual for details.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
• Small Footprint - Extremely lightweight with a compact foot-
print, it is a perfect fit for any application.
• Quality Condenser Coils - The coil is constructed of alumi-
num microchannel tubing and enhanced aluminum fins for
reduced size and increased efficiency.
• Coil Protection - Coils are protected from damage by a slot-
ted, stamped steel coil guard and secondary polymer mesh.
• Optional Factory E-Coat - Available ElectroFin
on select models.
• Protected Compressor - Compressors are protected inter-
nally by a high pressure relief valve and a temperature sen-
sor, and externally by the system high pressure switch. A
factory installed liquid line filter-drier further protects the
compressor against moisture and debris.
• Environmentally Friendly Refrigerant - The next genera-
tion refrigerant R-410A delivers environmentally friendly per-
formance with zero ozone depletion.
• Durable Finish - The cabinet is made of G90-equivalent pre-
painted steel, with special primer formulas and matte cham-
pagne texture to insure less fading when exposed to sun-
light.
The coated steel wire fan guard and pre-treated,
galvanized steel chassis components resist corrosion and
rust creep.
• Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections. The
unit is factory charged for a 15-foot lineset. The small base
dimension means less space is required on the ground or
roof.
• Top Discharge - Warm air from the top mounted fan is blown
up, away fro0m the structure and any landscaping. This
allows compact location on multi-unit applications.
• Low Operating Sound Levels - The upward air flow carries
the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the condenser coil muffle the nor-
mal fan motor and compressor operating sounds.
• Low Maintenance - Long life, permanently lubricated motor-
bearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connec-
tions and a single panel covering the electrical controls make
for easy servicing of the unit.
• Secured Service Valves - Secured, re-usable service
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
• Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.
840569-YTG-B-1012
®
coated coil

Advertisement

loading

Summary of Contents for York YCJD18

  • Page 1 1.5 THRU 5 NOMINAL TONS ® • Optional Factory E-Coat - Available ElectroFin coated coil MODELS: YCJD18 THRU 60 on select models. • Protected Compressor - Compressors are protected inter- nally by a high pressure relief valve and a temperature sen- sor, and externally by the system high pressure switch.
  • Page 2 840569-YTG-B-1012 Physical and Electrical Data YCJD18 YCJD24 YCJD30 YCJD36 YCJD42 YCJD48 YCJD60 MODEL S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S2(H)(E) S41S1(H)(E) S41S1(E) Unit Supply Voltage 208-230V, 1 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 10.0 12.4 14.7 17.9 21.5 21.1...
  • Page 3 840569-YTG-B-1012 System Charge for Various Matched Systems YCJD18 YCJD24 YCJD30 YCJD36 YCJD42 YCJD48 YCJD60 Outdoor Unit S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S1(H)(E) S41S2(H)(E) S41S1(H)(E) S41S1(E) 0.048/4F1 0.055/4F1 0.061/4F1 0.065/4G1 0.073/4G1 0.073/4H1 0.087/4J1 Required Orifice or TXV 3,4,5 Additional Charge, oz. Indoor Unit AHE18B –...
  • Page 4 840569-YTG-B-1012 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH AIR HANDLERS AHE18B 17.5 – 17.9 13.8 14.75 12.25 AHR18B 17.5 – 17.8 13.8 13.00 11.00...
  • Page 5 840569-YTG-B-1012 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH AIR HANDLERS AHE42D 24.5 – 1385 42.0 30.6 14.25 12.00 AHE48D 24.5 –...
  • Page 6 840569-YTG-B-1012 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings) COIL COOLING CFM RANGE NET MBH UNIT MODEL RATED (MIN.-MAX.) MODEL WIDTH SEER TOTAL SENS. 13 SEER AC COIL ONLY RATINGS FC/MC/PC18 14.5,17.5 450-750 17.5 12.9 13.00 11.00 YCJD18S41S1(H)(E)
  • Page 7 840569-YTG-B-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 14.5 FC/MC/PC18A 17.5 12.7 14.50 12.50 T*(8,L)V*A12 14.5 UC18A 17.5 12.7...
  • Page 8 840569-YTG-B-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES Y*(8,L)C*A12 14.5 FC/MC/PC37A 24.0 17.0 14.00 12.00 Y*(8,L)C*A12 14.5 UC36A 23.6...
  • Page 9 840569-YTG-B-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 14.5 FC/MC/PC37A 33.8 23.0 13.50 11.00 T*(8,L)V*B12 17.5 FC/MC/PC43B 1210...
  • Page 10 840569-YTG-B-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*B12 17.5 FC/MC/PC43B 1270 41.0 28.8 13.25 11.25 T*(8,L)V*C16 21.0 FC/MC/PC43C...
  • Page 11 840569-YTG-B-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES T*9(C,V)*C20 21.0 FC/PC60C 1445 42.0 29.8 13.25 11.25 T*9(C,V)*C20 21.0 FC64D...
  • Page 12 840569-YTG-B-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES Y*(8,L)C*C20 21.0 FC64D 1410 42.0 30.8 14.25 12.00 Y*(8,L)C*C20 21.0 UC48C...
  • Page 13 840569-YTG-B-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES Y*(8,L)C*C20 21.0 FC/PC60C 1625 48.0 35.0 13.50 11.50 Y*9C*C16 21.0 FC/MC/PC48C...
  • Page 14 840569-YTG-B-1012 ACCESSORIES Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and Refer to Price Manual for specific model numbers. installation, refer to the UPGNET “Low Voltage Wiring Diagram” Off Cycle Timer Delay - Provides a 5-minute off cycle to pre- document to select and apply controls.
  • Page 15: Ahr18B

    840569-YTG-B-1012 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD18S41S1(H)(E) INDOOR COIL MODEL NO. FC/MC/PC18 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 16.3 18.4 18.3 20.1 20.7 17.5 19.0 18.7 20.2 20.9 18.7 19.6 19.1 20.3 21.1 S.C.
  • Page 16: Ahr24B

    840569-YTG-B-1012 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD24S41S1(H)(E) INDOOR COIL MODEL NO. FC/MC/PC36 IDCFM 1000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 20.5 25.5 25.4 27.0 28.2 22.6 26.7 26.5 28.3 29.5 24.7 28.0 27.7 29.6 30.8 S.C.
  • Page 17 840569-YTG-B-1012 Furnaces Coils T.C. S.C. Furnaces Coils T.C. S.C. T*9X*A10 FC/MC/PC32A 1.00 1.01 0.94 T*(8,L)V*A12 FC/MC/PC32A 1.00 1.02 0.96 T*9X*A10 FC/MC/PC36A 1.01 1.01 0.94 T*(8,L)V*A12 FC/MC/PC36A 1.00 1.01 0.92 T*9X*A10 FC/MC/PC37A 1.02 1.02 0.95 T*(8,L)V*A12 FC/MC/PC37A 1.00 1.02 0.92 T*9X*B12 FC/MC/PC36B 1.00 1.01...
  • Page 18: Ahr30B

    840569-YTG-B-1012 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD30S41S1(H)(E) INDOOR COIL MODEL NO. FC/MC/PC32 IDCFM 1000 1200 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 30.2 33.4 32.8 35.2 36.5 31.7 33.9 33.4 35.5 36.7 33.2 34.3 34.1 35.9 36.9...
  • Page 19 840569-YTG-B-1012 Furnaces Coils T.C. S.C. Furnaces Coils T.C. S.C. T*9(C,V)*C20 FC/MC/PC43C 1.03 1.05 0.95 T*(8,L)V*A12 FC/MC/PC32A 1.01 1.04 1.01 T*9X*B12 FC/MC/PC35B 1.03 1.09 0.94 T*(8,L)V*A12 FC/MC/PC37A 1.03 1.04 0.98 T*9X*B12 FC/MC/PC43B 1.03 1.09 0.99 T*(8,L)V*B12 FC/MC/PC35B 1.02 1.02 0.98 T*9X*C16 FC/MC/PC35C 1.03 1.07...
  • Page 20: Ahv42D

    840569-YTG-B-1012 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD36S41S1(H)(E) INDOOR COIL MODEL NO. FC/MC/PC37 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 35.3 37.4 37.0 39.3 40.4 36.3 38.1 37.4 39.7 40.2 37.3 38.8 37.8 40.1...
  • Page 21 840569-YTG-B-1012 Furnaces Coils T.C. S.C. Furnaces Coils T.C. S.C. T*9X*C16 FC/MC/PC43C 1.01 1.02 0.98 T*(8,L)V*A12 FC/MC/PC37A 0.97 0.93 0.97 T*9X*C16 FC/MC/PC48C 1.02 1.04 0.98 T*(8,L)V*B12 FC/MC/PC43B 1.01 1.02 1.01 T*9X*C16 UC48C 0.99 1.00 0.97 T*(8,L)V*C16 FC/MC/PC43C 1.02 1.02 0.97 T*9X*C20 FC/MC/PC43C 1.00 0.99...
  • Page 22 840569-YTG-B-1012 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD42S41S2(H)(E) INDOOR COIL MODEL NO. FC/MC/PC43 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 41.8 43.9 43.7 47.2 49.9 43.3 45.0 44.7 47.9 50.9 44.7 46.0 45.7 48.5...
  • Page 23 840569-YTG-B-1012 Furnaces Coils T.C. S.C. Furnaces Coils T.C. S.C. T*(8,L)X*C16 FC/MC/PC43C 1.01 1.04 0.95 T*9X*C20 FC/MC/PC60D 1.01 1.01 0.95 T*(8,L)X*C16 FC/MC/PC48C 1.01 1.01 0.93 T*9X*C20 FC/MC62D 1.01 1.03 0.95 T*(8,L)X*C16 FC/MC/PC48D 1.01 1.01 0.93 T*9X*C20 FC/PC60C 1.01 1.01 0.95 T*(8,L)X*C16 FC/MC/PC60D 1.01 1.01...
  • Page 24 840569-YTG-B-1012 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD48S41S1(H)(E) INDOOR COIL MODEL NO. FC/MC/PC48 IDCFM 1400 1600 1800 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 49.7 51.4 50.5 55.8 54.6 52.0 53.1 51.9 56.3 55.4 54.4 54.7 53.2 56.9...
  • Page 25 840569-YTG-B-1012 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YCJD60S41S1(E) INDOOR COIL MODEL NO. FC/MC/PC60 IDCFM 1600 1800 2000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 55.5 55.5 61.1 59.4 62.4 64.9 57.7 62.9 60.1 63.8 66.9 59.9 64.7 60.8...
  • Page 26 NOTES Subject to change without notice. Published in U.S.A. 840569-YTG-B-1012 Copyright © 2012 by Johnson Controls, Inc. All rights reserved. Supersedes: 840569-YTG-A-0612 York International Corp. 5005 York Drive Norman, OK 73069...

This manual is also suitable for:

Ycjd30Ycjd24Ycjd42Ycjd48Ycjd60Ycjd36