Loop Test; Error Codes Loop Test - Philips DVD 950 Service Manual

Hide thumbs Also See for DVD 950:
Table of Contents

Advertisement

GB 52
7.
7.3.4

LOOP TEST

At the start of the loop test, the display will show the result of
the interactive player test:
Figure 7-30
The left side of the display contains a 3-digit code, which can
have a value between 000 and 111. These values are to be
interpreted as follows:
Displayed
Indication for each module
Value
Basic Engine
000
ok
001
ok
010
ok
011
ok
100
faulty
101
faulty
110
faulty
111
faulty
Figure 7-31

ERROR CODES LOOP TEST

ERROR CODE
0601
0901
1101
1102
1103
1104
1201
1202
1203
1204
1301
1302
1303
1304
1601
5201
5202
5203
5204
5401
5402
5403
5404
DVD 950
DIAGNOSTIC SOFTWARE : SCRIPT INTERFACES
CL 96532065_030.eps
120799
Mono
Display
PCB
PCB
ok
ok
ok
faulty
faulty
ok
faulty
faulty
ok
ok
ok
faulty
faulty
ok
faulty
faulty
CL 96532065_031.eps
120799
NUCLEUS NUMBER ERROR DESCRIPTION
6
9
11
12
13
16
52
54
The loop test will perform the same nuclei as the dealer test,
but it will loop through the list of nuclei indefinitely. The display
of the DVD player will display not only the three digits indicating
correct/faulty modules and the last found error code (as
mentioned, faults are detected as far as they can be within the
scope of the diagnostic software), but also a loop counter
indicating how many times the loop has been gone through.
Example:
FAULTY
MODULE(S)
The number after the hyphen indicates the number of times the
loop test has been performed; the 4 digits at the right side of the
display show the last error that was found when running the
loop test: the leftmost two digits of this code indicate which
nucleus resulted in a fault; the rightmost two digits refer to the
faultcode within that nucleus. For further explanation of this
error code, see list of error codes below.
Calculated checksum of FLASH is not correct
The DVD DRAM is faulty
I2C bus busy before start
NVRAM access time-out
No NVRAM Acknowledge
NVRAM reply time-out
I2C bus busy
I2C bus not working
Slave controller not responding
Slave response is not correct
Parity error from basic engine to serial
Parity error from serial to basic engine
No communication between serial and basic engine
Communication time-out error
The SDRAM is faulty
I2c bus busy
I2c bus not working
Colour setup controller not responding
Colour setup controller response not correct
I2c bus busy
I2c bus not working
Scart switch controller not responding
Scart switch controller response not correct
Figure 7-33
LOOP
COUNTER
NUCLEUS
ERROR
CL 96532065_032.eps
120799
Figure 7-32
CL96532126_021.eps
261099

Hide quick links: