Maintenance

Bleed Off

The bleed off should be checked to ensure it runs continuously and that there is no buildup of mineral
deposits in or on your air conditioner. White deposits indicate high mineral content and the bleed off
system should be checked.
In areas of poor water quality (where total dissolved solids are greater than 300 p.p.m.) increase the
bleed rate.
Pump Operation
Check the pump spins freely and that the strainer is
clean. Ensure the water slinger washer is in place on the
stainless steel shaft under the motor above the water
line.
After a long idle period, the pump may stop rotating due
to a mineral build up on the stainless shaft adjacent to
the motor. To free the pump shaft, remove mineral build
up and rotate the shaft using fingers or suitable sized
pliers. See diagram.
Spraying the area with suitable water displacement
lubricate (such as WD-40®) may assist.
In areas of low voltage, the pump may not provide
enough water to wet the filters. To rectify, increase
the water flow rate by turning Dialflo, as shown on
page 13.

Electrical

No general maintenance is
required to the electrical
system.
Electrical connections and maintenance
should only be carried out by a qualified
electrician.