c.
The raise button may now be released. The ramp
will lower when the button is released.
23. Place the dock leveler in both dock leveler storage
position and full below dock end load position. If lip is
being supported by the curb steel in either position, a
deflector plate must be created to allow leveler to store
and reach its full below dock position without getting
hung up on the pit floor.
Improper installation that allows the pendant dock leveler
lip to support the weight of the dock leveler could result
in death or serious injury. It is sometimes necessary to
install lip deflector plates to avoid any chance of the
pendant lip supporting the weight of the dock leveler
either near dock level or during a below dock end load.
24. Permanently
mount
WARNING and OPERATING instruction placard on the
wall near the dock leveler control. See Fig. 19. Make
sure the customer gets the user's manual and is properly
trained.
25. Operate the dock leveler four times through the complete
cycle to check operation. (See Operation section, page
25.)
noTe:
If you have any problems or questions using or operating
the dock leveler, contact your supervisor or local Kelley
distributor for assistance.
26. Optional (where applicable), install rear angle cap plugs
(part number 6004488) into adjustment socket holes.
Press cap flush with top surface to rear angle. See Fig.
20.
March 2014
6004753N — Hydraulic Dock Leveler - One Button Control — Safe
the
laminated
dock
leveler
insTaLLaTion,
Fig. 19
O P
E R
A T
IO N
S
Fig. 20
Cap plug
®
continued
Warning and operating
instruction placard
Rear angle
T
Frame
©2014 4Front Engineered Solutions, Inc.