Specifications; Ordering Information; Installation - Honeywell H1008A Product Data

Automatic humidity controls
Table of Contents

Advertisement

H1008A,D AUTOMATIC HUMIDITY CONTROL

SPECIFICATIONS

IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances. Therefore,
this unit may not exactly match the listed
specifications. Also, this product is tested under
closely controlled conditions and some minor
differences in performance can be expected if those
conditions are changed
TRADELINE® Models:
H1008A,D Automatic Humidity Control with HumidiCalc+
Software: Includes template and four mounting screws.
Electrical Ratings:
Power Supply: 18-30 Vac, 60 Hz.
Power Consumption: 2.5 VA at 27 Vac.
Relay Contacts:
Inductive: 2A full load, 10A locked rotor at 24 Vac.
Resistive: 2A
Thermostat/Furnace Load: 11 mA maximum at 24 Vac.
Temperature Ratings:
Operating Range: 45° to 88°F (7° to 31°C).
Storage Range: -40°F to 150°F (-40° to 66°C).
Humidity Ratings:
Always dehumidifies at 58° and above dewpoint.
Allows humidification/dehumidification at 50°F and below
dewpoint.
Does not allow humidification when dewpoint is above 50°F.
Dimensions:
Refer to Fig. 1.
Accessories:
C7089H Outdoor Temperature Sensor.

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1.
Your local Home and Building Control Sales Office (check white pages of your phone directory).
2.
Home and Building Control Customer Logistics
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000
In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N7.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0207—3
4-7/32 (107)
5-1/4 (133)
Fig. 1. H1008A,D dimensions in in. (mm).

INSTALLATION

When Installing this Product...
1. Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous
condition.
2. Check the ratings given in the instructions and on the
product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product operation
as provided in these instructions.
CAUTION
Voltage Hazard.
Power supply can cause electrical shock.
Disconnect power supply before beginning
installation.
2
7/16 (11)
1-17/32
(39)
4-7/32
(107)
3-1/8
(79)
1-31/32 (50)
M12830A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1008d

Table of Contents