Electrical connection

The appliance is equipped with a power cord and plug
(Y-type connection, the cord can only be replaced by the
manufacturer, the assistance centre or a qualified installer).
If using a socket near the appliance, insert the plug.
Before connecting the conditioner check that:
-
The power supply voltage and frequency values comply
with the data plate of the appliance.
-
The power supply line is provided with a suitable earth
connection and that it is dimensioned for the maximum
absorption of the conditioner (minimum cable section
equal to 1.5 mm
2
).
-
Power is only supplied using a suitable socket through
the supplied plug.
If the supply cable is replaced this has to be done
exclusively by the technical assistance service or by
authorised personnel and in compliance with current
national regulations.
The appliance must be connected to 230V/50 Hz mains
via an omnipolar switch with a contact opening distance
of minimum 3 mm, or using a device enabling the
complete disconnection of the appliance in overvoltage
III category conditions. It is possible to carry out the
electrical connection using a cable inside of the wall as
indicated in the installation template (recommended for
installations in the upper part of the wall).
CP presence contact input connection
When the CP contact opens (very low voltage, connected to
a free non-live contact) the appliance is put is stand-by and
CP appears on the display.
Using this contact, it is possible to connect an external
device that inhibits the functioning of the appliance such
as: open window contact, on/off remote, infrared presence
sensors, enabling badge, etc.
We recommend using a double insulation cable.
12
Soloclim
Please check that the power supply is provided with
suitable protections against overloads and/or short-circuits
(using a 10 at delay fuse or other equivalent devices is
recommended).
To prevent any risk of electrocution, always disconnect the
main circuit breaker before making electric connections or
performing any maintenance on the units.
To carry out direct connections and substitute the power
cord using the cable in the wall, proceed as follows:
-
Remove the upper grill.
-
Remove the two plastic side panels, by lifting them
upwards.
-
Undo the front panel fixing screws.
-
Remove the front panel.
-
Disconnect the power cord by unscrewing the 3 screws
from the terminal board.
-
Connect the wall cable checking that the power supply
line is provided with a suitable earth connection and
that it is dimensioned for the maximum absorption
of the conditioner (minimum cable section equal to
1.5mm
).
2
A
230V/50 Hz Electrical power supply terminal board
B
CP presence contact
1
Upper grill
2
Plastic side panels
3
Front panel
4
Fixing screws