Comtech EF Data DT-4572 Installation And Operation Manual page 82

X-band down converter
Hide thumbs Also See for DT-4572:
Table of Contents

Advertisement

DT4572 X-Band Down Converter
Remote Control
B.6.4.8 P
M
ACKED
Packed Maintenance Status: <DEV/PACRMS_'cr'
Confirmation:
where:
B.6.4.9 P
U
ACKED
Packed Utility Status:
Confirmation:
where:
S
AINTENANCE
TATUS
>DEV/PACRMS_aabbccddeeeffgghhii'cr''lf']
aa = V15 scaled 123mV per count (0x00 - 0xFF)
bb = V14 scaled 123mV per count (0x00 - 0xFF)
bc = VCC scaled 39mV per count (0x00 - 0xFF)
dd = V5D scaled 39mV per count (0x00 - 0xFF)
eee = signed Temperature in degrees C (-10 to +60)
ff = IFLO tune scaled 67mV per count (0x00 - 0xFF)
gg = SUM tune scaled 54mV per count (0x00 - 0xFF)
hh = COARSE tune scaled 78mV per count(0x00 - 0xFF)
ii = FINE tune scaled 89mV per count (0x00 - 0xFF)
S
TILITY
TATUS
<DEV/PACRUS_'cr'
>DEV/PACRUS_abbcdeeffghhii'cr''lf']
a = 0=EIA-232C, 1=EIA-485
bb = Address in hex (01 to FF)
c = 0 if Baud Rate 38400
= 1 if Baud rate 19200
= 2 if Baud rate 9600
= 3 if Baud rate 4800
= 4 if Baud rate 2400
= 5 if Baud rate 1200
d = 0 if Data Format 8-N-1
= 1 if Data Format 7-E-2
= 2 if Data Format 7-O-2
ee = Osc. Adjust in hex (00 to FF)
ff = Slope Adjust times by 10 (00 to 10)
g = Always 0, unused
hh = LCD Contrast (0 to 30)
ii = LCD Brightness (0 to 30)