Daikin FBQ20DAVMK Installation Manual

Split system ceiling mounted duct type
Hide thumbs Also See for FBQ20DAVMK:

Advertisement

Available languages

Available languages

Quick Links

00_CV_3PN06583-10W.fm Page 1 Thursday, March 24, 2011 8:56 AM

SPLIT SYSTEM

‫ﺍﻟﻨﻈﺎﻡ ﺍﻟﻤﻨﻘﺴﻢ‬
MODELS
‫ﺍﻟﻄﺮﺯ‬
(Ceiling mounted duct type)
FBQ20DAVMK
FBQ24DAVMK
FBQ36DAVMK
FBQ45DAVMK
FBQ48DAVMK
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

INSTALLATION MANUAL

‫ﺩﻟﻴﻞ ﺍﻟﺘﺮﻛﻴﺐ‬
(‫)ﺗﻜﻴﻴﻒ ﺳﻘﻒ ﻣﺰﻭﺩ ﺑﻤﺠﺮﻯ ﻫﻮﺍﺋﻲ‬
.‫ﺍﺣﺘﻔﻆ ﺑﻬﺬﺍ ﺍﻟﺪﻟﻴﻞ ﻓﻲ ﻣﻜﺎﻥ ﻳﺴﻬﻞ ﺍﻟﻮﺻﻮﻝ ﺇﻟﻴﻪ ﻟﻠﺮﺟﻮﻉ ﺇﻟﻴﻪ ﻓﻴﻤﺎ ﺑﻌﺪ‬

Air Conditioner

‫ﺟﻬﺎﺯ ﺗﻜﻴﻴﻒ ﺍﻟﻬﻮﺍء‬
.‫ﺍﻗﺮﺃ ﻫﺬﻩ ﺍﻹﺭﺷﺎﺩﺍﺕ ﺑﻌﻨﺎﻳﺔ ﻗﺒﻞ ﺍﻟﺘﺮﻛﻴﺐ‬
English
‫ﺍﻟﻌﺮﺑﻴﺔ‬

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FBQ20DAVMK

  • Page 1: Installation Manual

    ‫ﺍﻟﻌﺮﺑﻴﺔ‬ ‫ﺍﻟﻨﻈﺎﻡ ﺍﻟﻤﻨﻘﺴﻢ‬ ‫ﺟﻬﺎﺯ ﺗﻜﻴﻴﻒ ﺍﻟﻬﻮﺍء‬ MODELS ‫ﺍﻟﻄﺮﺯ‬ (‫)ﺗﻜﻴﻴﻒ ﺳﻘﻒ ﻣﺰﻭﺩ ﺑﻤﺠﺮﻯ ﻫﻮﺍﺋﻲ‬ (Ceiling mounted duct type) FBQ20DAVMK FBQ24DAVMK FBQ36DAVMK FBQ45DAVMK FBQ48DAVMK READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. .‫ﺍﻗﺮﺃ ﻫﺬﻩ ﺍﻹﺭﺷﺎﺩﺍﺕ ﺑﻌﻨﺎﻳﺔ ﻗﺒﻞ ﺍﻟﺘﺮﻛﻴﺐ‬...
  • Page 2: Table Of Contents

    01_EN_3PN06583-10W.fm Page 1 Thursday, March 24, 2011 9:03 AM FBQ20DAVMK FBQ24DAVMK SPLIT SYSTEM Air Conditioner Installation manual FBQ36DAVMK FBQ45DAVMK FBQ48DAVMK CONTENTS 1. SAFETY PRECAUTIONS....................1 2. BEFORE INSTALLATION ....................4 3. SELECTING INSTALLATION SITE................6 4. PREPARATIONS BEFORE INSTALLATION ..............7 5. INDOOR UNIT INSTALLATION ..................9 6.
  • Page 3 01_EN_3PN06583-10W.fm Page 2 Thursday, March 24, 2011 9:03 AM • Install the air conditioner on a foundation strong enough to withstand the weight of the unit. A foundation of insufficient strength may result in the equipment falling and causing injury. •...
  • Page 4: Special Notice Of Product

    01_EN_3PN06583-10W.fm Page 2 Thursday, March 24, 2011 9:03 AM • Do not install the air conditioner in the following locations: 1. Where there is a high concentration of mineral oil spray or vapour (e.g. a kitchen). Plastic parts will deteriorate, parts may fall off and water leakage could result. 2.
  • Page 5: Before Installation

    01_EN_3PN06583-10W.fm Page 3 Thursday, March 24, 2011 9:03 AM 2. BEFORE INSTALLATION Do not exert pressure on the resin parts when opening the unit or when moving it after opening. Be sure to check the type of R410A refrigerant to be used before doing any work. (Using an incorrect refrigerant will prevent normal operation of the unit.) •...
  • Page 6 01_EN_3PN06583-10W.fm Page 4 Thursday, March 24, 2011 9:03 AM (1) - (13) Operation manual Installation manual Fig. 1 2-2 OPTIONAL ACCESSORIES • The optional remote controller are required for this indoor unit. • These are two types of remote controllers: wired and wireless. Select a remote controller according to customer request and install in an appropriate place.
  • Page 7: Selecting Installation Site

    01_EN_3PN06583-10W.fm Page 5 Thursday, March 24, 2011 9:03 AM It may result in insufficient cooling or Did you set the external static pressure? heating. Did you check that no wiring connection Electric shock or fire. screws were loose? b. Items to be checked at time of delivery * Also review the “1.
  • Page 8: Preparations Before Installation

    01_EN_3PN06583-10W.fm Page 6 Thursday, March 24, 2011 9:03 AM (2) Use suspension bolts for installation. Check if the location for the installation is strong enough to support the weight of the unit, reinforce it if necessary, and install using suspension bolts. (length: mm) Ceiling Floor surface...
  • Page 9 01_EN_3PN06583-10W.fm Page 7 Thursday, March 24, 2011 9:03 AM Inspection hatch 3 Case 2, 3 Inspection hatch 1 (Same as the indoor (450×450) Inspection hatch unit size +300 or more) Control box (Ceiling opening) Control box Control box Inspection hatch Ceiling Inspection hatch 2 (Same as the indoor...
  • Page 10: Indoor Unit Installation

    01_EN_3PN06583-10W.fm Page 8 Thursday, March 24, 2011 9:03 AM 5. INDOOR UNIT INSTALLATION 〈 It may be easier to install accessories (sold separately) before installing the indoor unit. Refer to the installation manuals provided to the accessories as well. 〉 As for the parts to be used for installation work, be sure to use the provided accessories and specified parts designated by our company.
  • Page 11: Refrigerant Piping Work

    01_EN_3PN06583-10W.fm Page 9 Thursday, March 24, 2011 9:03 AM 6. REFRIGERANT PIPING WORK 〈 For refrigerant piping of outdoor units, see the installation manual attached to the outdoor unit. 〉 〈Execute heat insulation work completely on both sides of the gas piping and the liquid piping. Otherwise, a water leakage can result sometimes.〉...
  • Page 12 01_EN_3PN06583-10W.fm Page 10 Thursday, March 24, 2011 9:03 AM Table 1 Flare dimensions Pipe size Tightening torque (N·m) Flare A (mm) φ 9.5 (3/8”) 32.7 – 39.9 12.8 – 13.2 R0.4-0.8 φ 15.9 (5/8”) 61.8 – 75.4 19.3 – 19.7 CAUTION •...
  • Page 13 01_EN_3PN06583-10W.fm Page 11 Thursday, March 24, 2011 9:03 AM Heat insulation procedure for liquid piping Insulation for fitting (4) (accessory) Flare nut joint Insulation material for piping (on unit side) Make sure that the seam faces upward. Attached to the surface. Middle sealing pad (7) (accessory) Main unit Clamp (8) (accessory)
  • Page 14: Drain Piping Work

    01_EN_3PN06583-10W.fm Page 12 Thursday, March 24, 2011 9:03 AM • Nitrogen should be set to 0.02MPa with a pressure-reducing valve if brazing while inserting nitrogen into the piping. (Refer to Fig. 9) • Do not use flux when brazing refrigerant piping. Therefore, use the phosphor copper brazing filler metal (BCuP-2: JIS Z 3264/B-Cu93P-710/795: ISO 3677) which does not require flux.
  • Page 15 01_EN_3PN06583-10W.fm Page 13 Thursday, March 24, 2011 9:03 AM NOTE Be sure to follow the instructions as below. • Do not connect the drain piping directly to a sewer that smells of ammonia. The ammonia in the sewer may reach through the drain piping and corrode the heat exchanger of the indoor unit.
  • Page 16: Duct Work

    01_EN_3PN06583-10W.fm Page 14 Thursday, March 24, 2011 9:03 AM • On completion of the drainage check, refer to the following illustration, and use the provided large sealing pad (6) and heat insulate the metal clamp (1) and drain hose (2). Make sure that the Large sealing pad (6) seam faces upward.
  • Page 17: Electric Wiring Work

    01_EN_3PN06583-10W.fm Page 15 Thursday, March 24, 2011 9:03 AM 9. ELECTRIC WIRING WORK WIRING INSTRUCTIONS • Electric wiring work must be conducted by electrician authorized by power companies. (Only licensed electrician can conduct electric work and earth connections.) • All wiring must be performed by an authorized electrician. •...
  • Page 18 01_EN_3PN06583-10W.fm Page 16 Thursday, March 24, 2011 9:03 AM (2) Lay the wires in the control box through the wire inlet on the side of the control box. Low-voltage wiring inlet • Remote controller wiring (Low voltage) High-voltage wiring inlet •...
  • Page 19 01_EN_3PN06583-10W.fm Page 17 Thursday, March 24, 2011 9:03 AM (3) Follow the instructions below, and lay the wires in the control box. • Wiring the units (High voltage) • Power supply wiring Fix the wires with clamp (8) (High voltage) to the wire fixing bracket •...
  • Page 20 01_EN_3PN06583-10W.fm Page 18 Thursday, March 24, 2011 9:03 AM CAUTION • After all the wiring connections are done, fill in any gaps in the through holes with putty or insulation (procured locally) to prevent small animals and insects from entering the unit from outside. (If any do get in, they could cause short circuits in the control box.) (5) Mount the provided wire fixing bracket (12) with Remote controller...
  • Page 21 01_EN_3PN06583-10W.fm Page 19 Thursday, March 24, 2011 9:03 AM Specifications for field wire. • Remote controller transmission and power supply wiring are field supply. Refer to Table 2. • Follow national laws and standards for wiring type (insulating sheath specifications, etc.) Table 2 Type Field fuses...
  • Page 22 01_EN_3PN06583-10W.fm Page 20 Thursday, March 24, 2011 9:03 AM • For group control remote controller, choose the remote controller that suits the indoor unit which has the most functions (as attached swing flap) Group control Outdoor unit 16 Outdoor unit 1 Outdoor unit 2 Indoor unit 1 Indoor unit 2...
  • Page 23: Field Setting

    01_EN_3PN06583-10W.fm Page 21 Thursday, March 24, 2011 9:03 AM (2) Turn the main/sub changeover switch on one of the two remote controller PC boards to “S”. (Leave the switch of the other remote controller set to “M”.) (Refer to Fig. 13) Fig.
  • Page 24 01_EN_3PN06583-10W.fm Page 22 Thursday, March 24, 2011 9:03 AM With Wireless Remote Controller Used Set the wireless remote controller address before using the wireless remote controller. For the setting method of the address, refer to the operation manual provided with the wireless remote controller.
  • Page 25 • Consult your Daikin representative if there is any change in the ventilation paths (e.g., the duct and air outlet) after the test operation is finished or the air conditioner is moved to another place.
  • Page 26: Test Operation

    01_EN_3PN06583-10W.fm Page 24 Thursday, March 24, 2011 9:03 AM 12. TEST OPERATION Refer to the section of “FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK AFTER INSTALLATION IS FINISHED” . • Make sure that wiring work for the outdoor units is completed. •...
  • Page 27 01_EN_3PN06583-10W.fm Page 25 Thursday, March 24, 2011 9:03 AM With the power on. Troubles can be monitored on the remote controller. Trouble shooting with the display on the liquid crystal display remote controller. 1. With the wired remote controller. (NOTE 1) When the operation stops due to trouble, operation lamp flashed, and “...
  • Page 28 01_EN_3PN06583-10W.fm Page 26 Thursday, March 24, 2011 9:03 AM High pressure abnormal (outdoor unit) Low pressure abnormal (outdoor unit) Compressor motor lock malfunction (outdoor unit) Outdoor fan motor lock malfunction Outdoor fan instantaneous overcurrent malfunction (outdoor unit) Electronic expansion valve faulty (outdoor unit) Discharge pipe temperature abnormal (outdoor unit) High pressure switch faulty (outdoor unit) Outdoor motor position signal malfunction (outdoor unit)
  • Page 29 01_EN_3PN06583-10W.fm Page 27 Thursday, March 24, 2011 9:03 AM Transmission error (indoor unit – outdoor unit) Wrong wiring between indoor and outdoor units or malfunction of the PC board mounted on the indoor and the outdoor units. If UF is shown, the wiring between the indoor and outdoor units is not properly wired. Therefore, immediately disconnect the power supply and correct the wiring.
  • Page 30 MEMO...
  • Page 31 FBQ20DAVMK FBQ24DAVMK FBQ36DAVMK FBQ45DAVMK FBQ48DAVMK...
  • Page 32 .‫قم بتركيب جهاز تكييف الهواء على قاعدة قوية بما يكفي لتحمل وزن الوحدة‬ .‫قد تؤدي القاعدة غير القوية بما يكفي إلى سقوط الجهاز والتسبب في إصابة‬ .‫قم بإجراء أعمال التركيب المحددة بعد األخذ في االعتبار الرياح القوية أو األعاصير أو الزالزل‬ .‫فقد...
  • Page 33 :‫ال تقم بتركيب جهاز تكييف الهواء في األماكن التالية‬ .)‫المواقع التي تحتوي على تركيز عال ٍ من رذاذ أو بخار الزيت المعدني (مثل المطبخ‬ .‫فستتلف األجزاء البالستيكية، وقد تسقط بعض األجزاء مما قد يؤدي إلى تسرب المياه‬ .‫المواقع التي تصدر بها الغازات التآكلية، مثل حمض الكبريتيك. باإلضافة إلى المناطق الغنية بالصوديوم مثل شواطئ البحار‬ .‫فقد...
  • Page 34 ‫2. قبل التركيب‬ .‫ال تضغط على األجزاء المعالجة بالراتنج عند فتح الوحدة أو عند تحريكها بعد فتحها‬ ‫ التي سيتم استخدامها قبل القيام بأية أعمال. (إن استخدام مادة تبريد غير صحيحة سيمنع التشغيل‬R410A ‫تأكد من التحقق من نوع مادة التبريد‬ ).‫العادي...
  • Page 35 )13( - )1( ‫دليل التشغيل‬ ‫دليل التركيب‬ 1 ‫الشكل‬ ‫2-2 ملحقات اختيارية‬ .‫يلزم استخدام وحدة التحكم عن ب ُعد االختيارية لهذه الوحدة الداخلية‬ .‫هذان نوعان من وحدة التحكم عن ب ُعد: سلكي والسلكي. حدد وحدة التحكم عن ب ُعد وفق ً ا لطلب العميل وقم بتركيبها في مكان مناسب‬ ).‫(عند...
  • Page 36 ‫ب. نقاط يجب التحقق منها في وقت التسليم‬ "‫* أيض ً ا قم بمراجعة "1. احتياطات السالمة‬ ‫حدد‬ ‫نقاط يجب التحقق منها‬ ‫هل قمت بإرفاق غطاء علبة التحكم وفلتر الهواء وشبكة مدخل الهواء وشبكة مخرج الهواء؟‬ ‫هل قمت بشرح العمليات بينما تقدم دليل اإلرشادات إلى العميل؟‬ ‫هل...
  • Page 37 ‫(2) استخدم مسامير التعليق للتركيب. تحقق مما إذا كان موقع التركيب قو ي ًا بما يكفي لتحمل وزن الوحدة، وتعزيزه إذا لزم األمر، وقم بالتركيب باستخدام‬ .‫مسامير التعليق‬ )‫(الطول: ملم‬ ‫السقف‬ ‫سطح األرض‬ )‫الحد األدنى 007 (مساحة الخدمة‬ ]‫[مكان التركيب المطلوب‬ .‫* يشير...
  • Page 38 3 ،2 ‫الحالتان‬ 3 ‫فتحة الفحص‬ 1 ‫فتحة الفحص‬ ‫(نفس حجم الوحدة‬ )450×450( ‫فتحة الفحص‬ )‫الداخلية +003 أو أكثر‬ )‫(فتحة السقف‬ ‫علبة التحكم‬ ‫علبة التحكم‬ ‫علبة التحكم‬ ‫فتحة الفحص‬ ‫السقف‬ 2 ‫فتحة الفحص‬ ‫(نفس حجم الوحدة‬ )‫الداخلية أو أكثر‬ ‫* حدد ب ُعد االرتفاع 3 من خالل المحافظة على‬ ‫منحدر...
  • Page 39 ‫5. تركيب الوحدة الداخلية‬ ❭.‫❬قد يكون من األسهل تركيب الملحقات (تباع على حدة) قبل تركيب الوحدة الداخلية. راجع أدلة التركيب المرفقة مع الملحقات أيض ً ا‬ .‫أما بالنسبة إلى األجزاء التي سيتم استخدامها ألعمال التركيب، تأكد من استخدام الملحقات المرفقة واألجزاء المخصصة المحددة من قبل شركتنا‬ .‫(1) تركيب...
  • Page 40 ‫6. أعمال توصيل أنابيب التبريد‬ ❭.‫❬لمعرفة المزيد عن توصيل أنابيب التبريد بالوحدة الخارجية، انظر دليل التركيب المرفق مع الوحدة الخارجية‬ >.‫<قم بتنفيذ أعمال العزل الحراري بشكل كامل على كال جانبي أنابيب الغاز وأنابيب السائل. وإال، يمكن أن يتسرب الماء في بعض األحيان‬ ‫،...
  • Page 41 1 ‫الجدول‬ ‫أبعاد الطرف الواسع‬ ‫الطرف الواسع‬ )‫عزم الربط (نيوتن متر‬ ‫حجم األنبوب‬ )‫ (مم‬A 13,2 – 12,8 39,9 – 32,7 )‫ 5,9 (3/8 بوصة‬φ 19,7 – 19,3 75,4 – 61,8 )‫ 9,51 (5/8 بوصة‬φ ‫تنبيه‬ .‫قد يؤدي اإلفراط في ربط صامولة التوسيع إلى كسرها و/أو التسبب في تسرب مادة التبريد‬ ‫ال...
  • Page 42 ‫إجراء العزل الحراري ألنابيب السائل‬ )‫عزل للتركيب (4) (ملحق‬ ‫وصلة صامولة التوسيع‬ ‫المادة العازلة لألنابيب‬ )‫(على جانب الوحدة‬ .‫تأكد من أن يكون وجه الدرزة ألعلى‬ .‫معلقة على السطح‬ )‫بطانة منع التسرب الوسطى (7) (ملحق‬ ‫الوحدة الرئيسية‬ )‫المشبك (8) (ملحق‬ ‫قم بلف مادة العزل حول‬ ‫جزء...
  • Page 43 )9 ‫يجب ضبط النيتروجين على 20,0 ميغاباسكال بصمام خفض الضغط إذا تم اللحام بالنحاس عند إدخال النيتروجين إلى األنابيب. (راجع الشكل‬ ‫ال تستخدم الدفق عند لحام أنابيب التبريد بالنحاس. وبالتالي، استخدم معدن مالئ لحام النحاس والفسفور‬ .‫) والذي ال يتطلب وجود دفق‬BCuP-2: JIS Z 3264/B-Cu93P-710/795: ISO 3677( ‫(الدفق...
  • Page 44 ‫مالحظة‬ .‫تأكد من اتباع اإلرشادات على النحو التالي‬ .‫ال تقم بتوصيل أنابيب التصريف مباشرة بمجرى التصريف الذي تفوح منه رائحة األمونيا‬ .‫قد تصل األمونيا الموجودة في المجرى من خالل أنابيب التصريف وتسبب تآكل المبادل الحراري للوحدة الداخلية‬ .‫ال تقم بثني أو لي ّ خرطوم التصريف المرفق (2) من أجل عدم الضغط بقوة مفرطة على الخرطوم‬ ).‫(قد...
  • Page 45 ‫عند االنتهاء من التحقق من التصريف، راجع الرسم التوضيحي التالي واستخدم بطانة منع التسرب الكبيرة المرفقة (6) وقم بعزل المشبك المعدني‬ .)2( ‫حرار ي ًا (1) وخرطوم التصريف‬ ‫تأكد من أن يكون‬ )6( ‫بطانة منع التسرب الكبيرة‬ .‫وجه الدرزة ألعلى‬ )‫(ملحق‬...
  • Page 46 ‫9. أعمال توصيل األسالك الكهربائية‬ ‫إرشادات توصيل األسالك‬ ‫يجب أن تتم أعمال توصيل األسالك الكهربائية بواسطة فني كهرباء معتمد من شركات الطاقة. (ال يمكن إجراء أعمال الكهرباء والتوصيالت األرضية‬ ).‫إال من خالل فني الكهرباء المعتمد‬ .‫يجب أن تتم جميع توصيالت األسالك بواسطة فني كهرباء معتمد‬ .‫تأكد...
  • Page 47 ‫(2) ضع األسالك في علبة التحكم من خالل‬ .‫مدخل األسالك على جانب علبة التحكم‬ ‫مدخل توصيل األسالك ذات الجهد المنخفض‬ ‫توصيل أسالك وحدة التحكم عن ب ُعد‬ )‫(جهد منخفض‬ ‫مدخل توصيل األسالك ذات الجهد العالي‬ ) ٍ ‫توصيل أسالك الوحدات (جهد عال‬ ) ٍ...
  • Page 48 .‫(3) اتبع اإلرشادات التالية، وضع األسالك في علبة التحكم‬ ‫توصيل أسالك الوحدات (جهد‬ ) ٍ ‫عال‬ ‫توصيل أسالك مصدر إمداد‬ )8( ‫قم بتثبيت األسالك بواسطة مشبك‬ ) ٍ ‫الطاقة (جهد عال‬ ‫بكتيفة تثبيت السلك‬ ‫توصيل األسالك األرضية‬ .‫المرفقة مع علبة التحكم‬ ) ٍ...
  • Page 49 ‫تنبيه‬ ‫بعد االنتهاء من توصيالت جميع األسالك، قم بسد أي فراغات موجودة في الفتحات النافذة بمعجون أو مادة عازلة (يتم الحصول عليها محل ي ًا) لمنع‬ ‫دخول الحيوانات الصغيرة والحشرات في الوحدة من الخارج. (إذا تم دخول أي شيء، فقد يتسبب ذلك في حدوث قصر بالدائرة الكهربائية الموجودة‬ ).‫في...
  • Page 50 .‫المواصفات لسلك الحقل‬ .2‫ي ُعدإرسالوحدةالتحكمعن ب ُعدوتوصيلأسالكمصدرإمدادالطاقةمنلوازمالحقل.راجعالجدولرقم‬ ).‫اتبعالقوانينوالمعاييرالمحليةلنوعاألسالك(مواصفاتالغالفالعازل،إلخ‬ 2‫الجدول‬ ‫الطول‬ ‫الحجم(مم‬ ‫مواصفاتاألسالك‬ ‫صماماتالحقل‬ ‫النوع‬ )‫4محاور(بمافيذلكالسلكاألرضي‬ – 36 24 20 ‫توصيلأسالك‬ – ‫4محاور(بمافيذلكالسلك‬ ‫الوحدات‬ – 48 45 ‫األرضي)سلكمعزول‬ ‫سلكوحدةالتحكم‬ *‫الحداألقصى005م‬ 1,25-0,75 – – ‫عن ب ُعد‬ ‫2محور‬ ‫توصيلأسالكمصدر‬ – – ‫51أمبير‬...
  • Page 51 ‫بالنسبة لوحدة التحكم عن ب ُعد الخاصة بالتحكم في المجموعة، اختر وحدة التحكم عن ب ُعد التي تناسب الوحدة الداخلية التي تحتوي على أغلب الوظائف‬ )‫(مثل اللسان المتأرجح المرفق‬ ‫التحكم في المجموعة‬ 2 ‫الوحدة الخارجية‬ 16 ‫الوحدة الخارجية‬ 1 ‫الوحدة الخارجية‬ 1 ‫الوحدة...
  • Page 52 ‫". (اترك مفتاح وحدة التحكم عن‬S" ‫(2) أدر مفتاح التحويل بين رئيسي/فرعي على لوحات الدائرة المطبوعة ألحد وحدتي التحكم عن ب ُعد على الوضع‬ )13 ‫".) (راجع الشكل‬M" ‫ب ُعد األخرى على الوضع‬ 13 ‫الشكل‬ )‫(إعداد المصنع‬ ‫لوحة الدائرة‬ ‫المطبوعة لجهاز‬ ‫التحكم...
  • Page 53 ‫باستخدام جهاز تحكم عن ب ُعد السلكي‬ .‫قم بتعيين عنوان وحدة التحكم عن ب ُعد الالسلكية قبل استخدامها‬ .‫لمعرفة طريقة إعداد العنوان، ي ُرجى الرجوع إلى دليل التشغيل المرفق مع وحدة التحكم عن ب ُعد الالسلكية‬ ‫مالحظة‬ ‫تم تعيين "رقم الوضع" على قاعدة المجموعة. ومع ذلك، إلجراء إعداد الوضع لقاعدة وحدة سيتم تركيبها بأحد الغرف أو التحقق من اإلعداد الذي تم‬ .‫إجراؤه،...
  • Page 54 ‫إذا كان هناك أي تغيير بعد ضبط تدفق الهواء في مسارات التهوية (مثل المجرى ومخرج الهواء)، فتأكد من إعداد الضبط التلقائي لتدفق الهواء مرة‬ .‫أخرى‬ ‫ إذا كان هناك أي تغيير في مسارات التهوية (مثل المجرى ومخرج الهواء) بعد االنتهاء من عملية االختبار أو نقل جهاز‬Daikin ‫استشر وكيل‬ .‫تكييف الهواء إلى مكان آخر‬...
  • Page 55 ‫21. عملية االختبار‬ ‫راجع الجزء "للنقاط التالية، يجب توخي الحذر خالل‬ ."‫عملية التركيب والتحقق منها بعد االنتهاء من التركيب‬ .‫تأكد من اكتمال أعمال توصيل األسالك الخاصة بالوحدة الخارجية‬ .‫تأكد من أن أغطية علبة التحكم مغلقة على الوحدات الداخلية والخارجية‬ .‫بعد االنتهاء من أعمال تركيب أنابيب التبريد وأنابيب التصريف واألسالك الكهربائية، قم بتنظيف دواخل الوحدات الداخلية‬ .‫قم...
  • Page 56 .‫عند التوصيل بالطاقة. يمكن رصد المشكالت على وحدة التحكم عن ب ُعد‬ ■ .‫استكشاف المشكالت وإصالحها من خالل العرض على وحدة تحكم شاشة العرض البلورية المائية‬ )1 ‫باستخدام وحدة التحكم عن ب ُعد السلكية. (مالحظة‬ ‫" ويظهر رمز العطل على شاشة العرض البلورية المائية. في مثل هذه‬ "...
  • Page 57 )‫ضغط عال ٍ غير طبيعي (الوحدة الخارجية‬ )‫ضغط منخفض غير طبيعي (الوحدة الخارجية‬ )‫عطل في قفل محرك الضاغط (الوحدة الخارجية‬ ‫عطل في قفل محرك المروحة الخارجية‬ )‫عطل بسبب زيادة تيار لحظية في المروحة الخارجية (الوحدة الخارجية‬ )‫عطل في صمام التوسعة اإللكتروني (الوحدة الخارجية‬ )‫درجة...
  • Page 58 )‫خطأ في اإلرسال (الوحدة الداخلية - الوحدة الخارجية‬ ‫توصيل األسالك غير صحيح بين الوحدات الداخلية والخارجية أو تعطل لوحة الدائرة المطبوعة المثبتة على الوحدات الداخلية‬ .‫والخارجية‬ .‫، فإنه لم يتم توصيل األسالك بين الوحدات الداخلية والخارجية بشكل صحيح‬UF ‫إذا ظهرت‬ ‫وبالتالي،...
  • Page 60 00_CV_3PN06583-10W.fm Page 2 Th ursday, March 24, 2011 8:56 AM http;//www.daikin.com/global_ac/ 3P370016-1 M14N008...

This manual is also suitable for:

Fbq36davmkFbq24davmkFbq45davmkFbq48davmk

Table of Contents