Daikin FBQ50BV1A Operation Manual
Daikin FBQ50BV1A Operation Manual

Daikin FBQ50BV1A Operation Manual

Ceiling-mounted built-in type

Advertisement

OPERATION MANUAL

SPLIT SYSTEM

Air Conditioner

MODELS
(Ceiling-mounted built-in type)
FBQ50BV1A
FBQ60BV1A
FBQ71BV1A

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FBQ50BV1A

  • Page 1: Operation Manual

    OPERATION MANUAL SPLIT SYSTEM Air Conditioner MODELS (Ceiling-mounted built-in type) FBQ50BV1A FBQ60BV1A FBQ71BV1A...
  • Page 2 AVAILABLE TEST TEST...
  • Page 3 Thank you for purchasing this Daikin air condi- tioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file it...
  • Page 4: Table Of Contents

    CONTENTS NOTE • Contact your Daikin dealer in case of changing ILLUSTRATIONS..........[1] the combination or setting of group control and 1. WHAT TO DO BEFORE OPERATION ..1 two remote controllers control system. 2. SAFETY CONSIDERATIONS......1 3. OPERATION RANGE ........3 Names and functions of parts 4.
  • Page 5 Be sure to install an earth leakage breaker. WARNING Failure to install an earth leakage breaker may Avoid exposure of your body directly to the result in electric shocks, or fire. cold air for a long time, or avoid excessive The appliance is not intended for use by young exposure of your body to the cold air.
  • Page 6: Operation Range

    Consult with installation contractor for d. Where there are considerable voltage fluctua- cleaning the inside of the air conditioner. tions such as a factory or plant Wrong cleaning may make the plastics parts e. Vehicles and vessels broken or cause failure of water leakage or elec- f .
  • Page 7: Name And Function Of Each Switch And Display On The Remote Controller

    Refer to figure 1 on page [1] DISPLAY “ ” (PROGRAMMED TIME) • Operating procedure varies with heat pump type and cooling only type. Contact your Daikin dealer This display shows the PROGRAMMED TIME to confirm your system type. of the system start or stop.
  • Page 8 FAN OPERATION ........“ ” TEMPERATURE SETTING DRY OPERATION........“ ” • The function of this program is to decrease the Press TEMPERATURE SETTING button and humidity in your room with the minimum tem- program the setting temperature. perature decrease. •...
  • Page 9: Optimum Operation

    • Never place objects near the air inlet and the air PROGRAMMING TIME outlet of the unit. It may cause deterioration in the effect or stop in the operation. • Turn off the main power supply switch when it is Press the PROGRAMMING TIME button and set the time for stopping or starting the sys- not used for long periods of time.
  • Page 10: Not Malfunction Of The Air Conditioner

    B)Washing with water Cut off the power supply. • When the main power switch is turned on, some To clean the air filter, use soft brush and neutral detergent. watts of electricity is being used even if the sys- tem is not operating. Turn off the main power supply switch for saving Remove water and dry in the shade.
  • Page 11: Trouble Shooting

    It is necessary to clean the The system must be repaired by a qualified service inside of the indoor unit. Ask your Daikin dealer for person. details on cleaning the unit. This operation WARNING requires a qualified service person.
  • Page 12 • Check if the breaker is blown. Turn the power on with the breaker switch in the off position. Do not turn the power on with the breaker switch in the trip position. (Contact your dealer.) Switch Trip position Breaker 2.
  • Page 13 3P156215-7K EM06A004A (0607) FS...

This manual is also suitable for:

Fbq60bv1aFbq71bv1a

Table of Contents