Legacy Whirlpool LW 524 Owner's Manual page 31

Table of Contents

Advertisement

REGULAR MAINTENANCE PROCEDURES
Note: These are areas that will require the spa owner to perform routine maintenance. These are not
areas covered under the warranty of the spa.
CLEANING DIVERTER VALVES
Mineral deposits, grit and sand may get into the internal parts of the diverter valves over time. The
diverter valves may become difficult to turn or not turn at all.
Remove the handle from the top of diverter valve by gently prying up on both sides of the handle
assembly at the same time.
Turn the cap piece counter clockwise. It may be necessary to put a clean towel over the cap and
turn it with a wrench.
Once loose, the cap, internal rotor assembly and handle can be pulled up out of the white
plumbing fitting.
Wipe down the internal rotor assembly that attaches to the cap and handle.
Soak the internal rotor assembly in white vinegar.
The inner wall of the white plumbing fitting should also be wiped down. If the surface of the
white plumbing has become too abrasive, you can take wet, fine sandpaper and smooth it out.
Rinse the diverter internals and reassemble.
In the future, it is helpful to turn the diverter valve only when the pump is not on. Cleaning
your diverter valve should occur every time you drain your spa. Refer to Draining Your Spa in the
Regular Maintenance Procedures section.
CARE OF YOUR SPA COVER
Always cover your spa when not in use with an approved insulating spa cover by Master Spas. This
will greatly reduce energy consumption and will cause spa water to heat more rapidly. Water loss and
chemical usage will also be reduced.
• Be sure to lock down all straps on the cover after each use.
• Do not allow spa to sit uncovered in direct sunlight. This may cause damage to exposed surfaces of
spa and possible discoloration of spa fittings.
• Periodically hose off both sides of spa cover for maximum life of cover. See cover manual
instructions for detailed instructions on proper cover care.
• Keep cover open for 15 min. after adding chemicals to prevent off gas damage.
NOTE: If your spa is going to be left empty for prolonged periods, do not replace cover directly on
surface of spa. Place 2"-3" blocks between cover and spa. This allows for adequate ventilation
of cover and spa.
NOTE: The cover warranty is not part of the limited warranty provided with the spa. It is provided
through the cover manufacturer and may not be through Master Spas. Check the tags
and labeling on your cover to verify manufacturer and refer to the manufacturer's care,
maintenance and warranty information. Your dealer can help provide you with these details.
NOTE: Always turn water feature valve down so that the water features do not hit the cover when
the cover is closed.
CARE OF YOUR SPA CABINET
The spa cabinet is made from a UV resistant material. The cabinet requires only periodic cleaning with
a stream of water from a garden hose.
DO NOT DIVE.
DO NOT DIVE.
29
104

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lw inspireLw 730lLw 715Lw intrepidLw enterprise

Table of Contents