Names And Functions - Luxman P-750u Owner's Manual

Table of Contents

Advertisement

Names and Functions

Front panel
1
2
1. Operation indicator (OPERATION)
This blue indicator blinks for a short time to show that the
system is in preparation immediately after the operation
switch is turned on. No sound will be generated during this
period. The indicator will light up steadily when the timed
mute mode is cancelled and operation mode is activated.
If a short circuit or over-current is detected, DC voltage is
generated or the unit experiences an abnormally high op-
erating temperature, the indicator will blink to indicate that
mute mode has been activated. After resolving the cause
of the fault, the blue indicator should light up steadily, in-
dicating normal operation mode has been activated again.
If this indicator continues to blink after resolving the fault,
please contact your country's official LUXMAN distributor
for a repair or service.
2. Operation switch (OPERATION)
This switch turns on and off the power.
ATTENTION: when connecting input devices or connecting
the output to other audio equipment ensure that the power
is switched off.
ON: Turns on this unit's power. The blue operation in-
dicator light will blink and then light up steadily.
OFF: Turns this unit's power off.
5
3
4
5
6
7
8
9
3. Input selection switch (INPUT)
This switch toggles between the unbalanced line input
(LINE), balanced line 1 input (BAL LINE-1), and balanced
line 2 input (BAL LINE-2) which are located on the rear panel
of the unit.
4. Through output switch
(THROUGH OUT)
This switch enables the user connect the line input of the
unit directly to the through output terminals, for example a
CD player connected to the line input may be directly con-
nected to an output destination device such as an amplifi-
er. Set to on, this switch enables the direct through output
connection and the orange indicator will light up. Selecting
off disconnects the signal to the through output.
When the power to this unit is switched off, the line in-
put signal IS ALWAYS connected to the through output
terminals, regardless of this switch setting. Signals from
devices connected to the balanced line inputs are not
outputted from the through output terminals.