Wiring Connection - LG LT-C1260CL Service Manual

Ceiling cassette air conditioner
Table of Contents

Advertisement

5. Wiring Connection

• Open the control box cover and connect the Remote controller cord and Indoor power wires.
Power cord
• Heat Pump Model
1(L) 2(N)
Power Cord
• Cooling Model
1(L) 2(N)
Power Cord
The power cord connected to the outdoor unit should be complied
with the following specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufac-
turer or its service agent.
WARNING
Make sure that the screws of the terminal are free from looseness.
Control box cover
Remote control cord
In-Out connecting wire
Terminal Block of Indoor Unit
4(L) 5(N)
7
8
Terminal Block of Indoor Unit
4(L) 5(N)
7
8
NORMAL
CROSS-SECTIONAL
AREA 2.5mm
9
9
CAUTION
The connecting cable connected to the indoor and outdoor unit should
be complied with the following specifications (Rubber insulation,
type H05RN-F approved by HAR or SAA).
–17–
Terminal Block of Outdoor Unit
4(L) 5(N)
7
8
9
Terminal Block of Outdoor Unit
4(L) 5(N)
7
8
9
NORMAL
CROSS-SECTIONAL
AREA 0.75mm