APPENDIX D - STATUS CODES

© GEMPLUS
Status codes provided by the GPR400 are listed in the table below:
Code
00
04h
05h
10h
12h
14h
15h
16h
19h
1Ah
1Bh
1Dh
1Eh
1Fh
20h
Meaning
Command successfully executed.
Unknown reader command. The first byte of the
request is not a valid command type.
Unknown Smartcard driver. The driver was not
loaded.
Response error at card reset. The first byte of the
response (TS) is not valid.
The L parameter is not valid; chaining buffer overflow
or chaining Li value <> 28.
Unknown card type. The T parameter in the Define
Card Type command is not valid.
Card turned off. A Power Up command must be
given to the card prior to any other operation.
The V parameter is incorrect.
The Flash Memory is not present. The command is
not supported.
Error in an ISO format card command. The LN
parameter in the ISO header does not correspond to
the actual data length.
A command has been sent with an incorrect number
of parameters.
The TCK check byte of an asynchronous card
Answer To Reset is incorrect.
Memory access is incorrect.
Writing problem in the Flash Memory.
Bad TLV command type <T>.