This device is protected by a double insulation or by a reinforced insulation. No linking is required from the protection earth terminal to ensure electrical safety. Thank you for purchasing a C.A 5011 Multimeter. To get the best service from this instrument: - read this user’s manual carefully...
14 - Maintenance ............23 15 - Appendix ............57 1 - PRESENTATION The analogue and digital C.A 5011 multimeter is designed for the daily needs of professionals in electricity. It gives the true rms (TRMS) value. It has the following functions:...
2 - DESCRIPTION (See drawing in § 15 - APPENDIX) TERMINALS Ø 4 mm safety terminals COM : common, terminal that receives the black lead V Ω Ω Ω Ω Ω Hz : terminal that receives the red lead for voltages, resistances, diode test and frequencies 10A : terminal that receives the red lead for the 10 A ranges µ...
SWITCH Switch with 21 positions to select the functions and ranges and the OFF position. CONTROL KEYS NB: These secondary function keys are shown on the digital display. To switch on and off the display backlighting. N B: Auto off after 6 minutes To read the rms value and the possible DC or AC component depending on the signal present, DC or AC (see in Ch.3 - RMS value)
Page 6
3-1 DC In the case of a DC signal with AC component (ripple). "AUTO " is displayed when the instrument is switched on: reading of the DC component only V By successive presses on the “ ” key: reading of DC plus the AC component, of the AC component only and return to DC only.
4 - DC AND AC VOLTAGES Connect the leads to the multimeter and connect in parallel to the circuit to be tested. When the order of magnitude is not known, place the switch on the highest range then progressively lower to the appropriate range. Analogue reading: to get the voltage in V, multiply the value read on the appropriate scale by the reading coefficient shown in the table.
5 - DECIBELS Reminder. The measurement of an AC voltage can be expressed in decibels (symbol dB). The decibel is the ratio of two quantities or levels. Level N, in dB, of a voltage U has the mathematical expression: N dB) = 20 is the reference voltage of 0.775 V AC for a power P of 1 mΩ...
400 µ µ µ µ µ A A DC 4 mA 40 mA 400 mA 10 A Voltage drop 400 mV 450 mV 650 mV 399.9 µA 3.999 mA 39.99 mA 399.9 mA Max reading 1.000 A 10.00 A Digital Accuracy 1.5% rdg ±...
Degree of watertightness (NF EN 60529, ed 92): protection index IP 53 12 - TO ORDER Use the designations and references below. C.A 5011 ..............P01.1963.11A Supplied with a pair of leads with prods, 1 battery 9 V and this User’s manual Accessories and spares Carrying case (270 x 200 x 65 mm) ....
It is essential that all measuring instruments are regularly calibrated. For checking and calibration of your instrument, please contact our accredited laboratories (list on request) or the Chauvin Arnoux subsidiary or Agent in your country. 14-5 Repair Repairs under or out of guarantee: please return the product to...