Montageanleitung für Standardprofilsysteme (Originalsprachlichen Anweisungen) Manuel d’assemblage pour système d’huisserie standard (Instructions originales) Manual de montaje para sistema de cierre estándar (Instrucciones originales) Manual de montagem para sistema de ferragem padrão (Instruções originais) Ditec PAM30STD IP2275 • 2017-04-30 www.entrematic.com www.entrematic.com...
Page 2
Index General safety precautions Avvertenze generali per la sicurezza Allgemeine Sicherheitshinweise Consignes générales de sécurité Advertencias generales de seguridad Advertências gerais para a segurança Operating instruction Indicazioni di utilizzo Hinweise zum Gebrauch Indications d'utilisation Instrucciones de uso Indicações de uso Entrance/Exit door frame Serramento di entrata/uscita Eingangs-/Ausgangsprofil –...
Page 3
Vertical and horizontal section of 1 Sezione verticale e orizzontale 1 anta Vertikal- und Horizontalschnitt für Section verticale et horizontale 1 Sección vertical y horizontal de 1 hoja Secção vertical e horizontal de 1 folha moving door wing with beam with left- mobile con apertura a sinistra e trave 1 Fahrflügel mit Linksöffnung und vantail mobile avec ouverture à...
Page 4
Vertical and horizontal section of 1 Sezione verticale e orizzontale 1 anta Vertikal- und Horizontalschnitt für Section verticale et horizontale 1 Sección vertical y horizontal de 1 hoja Secção vertical e horizontal de 1 folha moving door wing and 1 fixed door wing mobile con apertura a destra, 1 anta 1 Fahrflügel mit Rechtsöffnung, 1 vantail mobile avec ouverture à...
Page 5
Vertical and horizontal section of 2 Sezione verticale e orizzontale 2 Vertikal- und Horizontalschnitt für 2 Section verticale et horizontale 2 Sección vertical y horizontal de 2 hojas Secção vertical e horizontal de 2 folhas moving door wings and 2 fixed door ante mobili, 2 ante fisse e sopraluce Fahrflügel, 2 Stehflügel und Oberlicht vantaux mobiles, 2 vantaux fixes et...
This symbol indicates instructions or notes regarding safety, to which special attention must be paid. This symbol indicates useful information for the correct functioning of the product. 1. General safety precautions This assembly and installation manual is intended for qualified personnel only. Read the instructions carefully before installing the product.
Page 7
Questo simbolo indica istruzioni o note relative alla sicurezza a cui prestare particolare attenzione. Questo simbolo indica informazioni utili al corretto funzionamento del prodotto. 1. Avvertenze generali per la sicurezza Il presente manuale di lavorazione ed assemblaggio è rivolto esclusivamente a personale qualificato. Leggere attentamente le istruzioni prima di iniziare l’installazione del prodotto.
Page 8
Dieses Symbol verweist auf Anweisungen oder Hinweise zur Sicherheit, auf die besonders geachtet werden muss. Dieses Symbol verweist auf nützliche Informationen für den Betrieb des Produkts. 1. Allgemeine Sicherheitshinweise Das vorliegende Montage und Installationshandbuch ist ausschließlich für das Fachpersonal bestimmt. Lesen Sie die Anleitungen vor der Montage des Produktes aufmerksam durch.
Page 9
Ce symbole indique les instructions ou les notes concernant la sécurité pour laquelle il faut être particulièrement attentif. Ce symbole indique les informations utiles pour le bon fonctionnement du produit. 1. Consignes générales de sécurité Le présent manuel d'assemblage et d'installation s'adresse uniquement à un personnel qualifié. Lire les instructions avec beaucoup d'attention avant d'installer le produit.
Page 10
Este símbolo indica instrucciones o notas relativas a la seguridad a las que prestar una atención especial. Este símbolo indica informaciones útiles para el funcionamiento correcto del producto. 1. Advertencias generales de seguridad Este manual de montaje e instalación está exclusivamente dirigido a personal cualificado. Lea detenidamente las instrucciones antes de comenzar la instalación del producto.
Êsse símbolo indica instruções ou notas relativas à segurança que requerem uma atenção particular. Êsse símbolo indica informações úteis para o correcto funcionamento do produto. 1. Advertências gerais para a segurança O presente manual de montagem e instalação é dirigido exclusivamente a profissionais especializados. Leia atentamente as instruções antes de iniciar a instalação do produto.
Page 12
4. Legend Moving door wing Anta mobile Fahrflügel Vantail mobile Hoja móvil Portinhola móvel Fixed door wing Anta fissa Seitenteil Vantail fixe Hoja fija Portinhola fixa Beam Trave Kämpferprofil Montant Viga Trave Frame Cornice Rahmen Cadre Marco Caixilho Overlight Sopraluce Oberlicht Imposte Montante...
Page 22
8. Applications Scale 1:2 The PAM30 door frames allow frames to be motorised with Ditec VALOR and VALOR REX S automations. VALOR and REXS automations are not included in the configuration. The examples of vertical and horizontal sections that follow, show (for illustrative purposes only) the VALOR automations.
Page 26
9. Vertical and horizontal section of 1 moving door wing with right-hand opening (standard version) L (min. 800, max. 1500) PL = L min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 27
10. Vertical and horizontal section of 1 moving door wing with right-hand opening T15N installed within doorway (standard version) L (min. 800, max. 2000) PL = L - 40 min. 10 LT min. = 2L - 2 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 28
11. Vertical and horizontal section of 1 moving door wing with left-hand opening (standard version) L (min. 800, max. 1500) PL = L min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 29
12. Vertical and horizontal section of 1 moving door wing with left-hand opening T17N (standard version) L (min. 800, max. 2000) PL = L - 40 min. 10 LT min. = 2L - 2 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 30
13. Vertical and horizontal section of 1 moving door wing with right-hand opening (french version) Valor only (not Rex-S) V4671 L (min. 800, max. 2000) PL = L min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 31
14. Vertical and horizontal section of 1 moving door wing with right-hand opening installed within doorway (french version) Valor only (not Rex-S) V4671 L (min. 800, max. 2000) PL = L - 40 min. 10 LT min. = 2L - 2 40.5 Horizontal section Vertical section...
Page 32
15. Vertical and horizontal section of 1 moving door wing with left-hand opening (french version) Valor only (not Rex-S) L (min. 800, max. 1500) PL = L min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 33
16. Vertical and horizontal section of 1 moving door wing with left-hand opening installed within doorway (french version) Valor only (not Rex-S) L (min. 800, max. 2000) PL = L - 40 min. 10 LT min. = 2L - 2 40.5 Horizontal section Vertical section...
Page 34
17. Vertical and horizontal section of 1 moving door wing with beam with right-hand opening (standard version) L (min. 800, max. 1500) PL = L min. 10 LT min. = 2L + 88 40.5 30 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 35
18. Vertical and horizontal section of 1 moving door wing with beam with right-hand opening T23N installed within doorway (standard version) L (min. 800, max. 2000) PL = L - 40 min. 10 LT min. = 2L - 2 40.5 30 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 36
19. Vertical and horizontal section of 1 moving door wing with beam with left-hand opening (standard version) L (min. 800, max. 1500) PL = L min. 10 LT min. = 2L + 88 40.5 30 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 37
20. Vertical and horizontal section of 1 moving door wing with beam with left-hand opening T25N installed within doorway (standard version) L (min. 800, max. 2000) PL = L - 40 min. 10 LT min. = 2L - 2 40.5 30 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 38
21. Vertical and horizontal section of 1 moving door wing with right-hand opening and overlight (standard version) L (min. 800, max. 1500) PL = L min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 39
22. Vertical and horizontal section of 1 moving door wing with right-hand opening T27N installed within doorway and overlight (standard version) L (min. 800, max. 2000) PL = L - 40 min. 10 LT min. = 2L - 2 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 40
23. Vertical and horizontal section of 1 moving door wing with left-hand opening and overlight (standard version) L (min. 800, max. 1500) PL = L min. 10 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 41
24. Vertical and horizontal section of 1 moving door wing with left-hand opening T29N installed within doorway and overlight (standard version) L (min. 800, max. 2000) PL = L - 40 min. 10 LT min. = 2L - 2 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 42
25. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with right-hand opening (french version) Valor only (not Rex-S) L (min. 1600, max. 4000) PL = (L - 43) / 2 LT min. = L + 85 22.5 Horizontal section Vertical section...
Page 43
26. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with right-hand opening installed within doorway (french version) Valor only (not Rex-S) L (min. 1650, max. 4000) PL = (L - 83) / 2 LT min. = L + 35 22.5 Horizontal section Vertical section...
Page 44
27. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with left-hand opening (french version) Valor only (not Rex-S) L (min. 1600, max. 4000) PL = (L - 43) / 2 LT min. = L + 85 22.5 Horizontal section Vertical section...
Page 45
28. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with left-hand opening installed within doorway (french version) Valor only (not Rex-S) L (min. 1650, max. 4000) PL = (L - 83) / 2 LT min. = L + 35 22.5 Horizontal section Vertical section...
Page 46
29. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with beam with right-hand opening (standard version) L (min. 1650, max. 3000) PL = (L - 68 - X) / 2 X (min. 30) LT min. = L - 20 22.5 Horizontal section Vertical section...
Page 47
30. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with beam with left-hand opening (standard version) L (min. 1650, max. 3000) PL = (L - 68 - X) / 2 X (min. 30) LT min. = L - 20 22.5 Horizontal section Vertical section...
Page 48
31. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with beam with right-hand opening (french version) Valor only (not Rex-S) L (min. 1650, max. 4000) PL = (L - 68 - X) / 2 X (min.
Page 49
32. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with beam with left-hand opening (french version) Valor only (not Rex-S) L (min. 1650, max. 4000) PL = (L - 68 - X) / 2 X (min.
Page 50
33. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with right-hand opening and overlight (standard version) L (min. 1650, max. 3000) PL = (L - 68 - X) / 2 X (min. 30) LT min. = L - 20 22.5 Horizontal section Vertical section...
Page 51
34. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with left-hand opening and overlight (standard version) L (min. 1650, max. 3000) PL = (L - 68 - X) / 2 X (min. 30) LT min. = L - 20 22.5 Horizontal section Vertical section...
Page 52
35. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with right-hand opening and overlight (french version) Valor only (not Rex-S) L (min. 1650, max. 4000) PL = (L - 68 - X) / 2 X (min.
Page 53
36. Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with left-hand opening and overlight (french version) Valor only (not Rex-S) L (min. 1650, max. 4000) PL = (L - 68 - X) / 2 X (min.
Page 54
37. Vertical and horizontal section of 2 moving door wings (standard version) L (min. 800, max. 3000) PL = L min. 10 min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 55
38. Vertical and horizontal section of 2 moving door wings (french version) Valor only (not Rex-S) L (min. 800, max. 3000) PL = L min. 10 min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 56
39. Vertical and horizontal section of 2 moving door wings with beam (standard version) L (min. 800, max. 3000) PL = L min. 10 min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 57
40. Vertical and horizontal section of 2 moving door wings with overlight (standard version) L (min. 800, max. 3000) PL = L min. 10 min. 10 LT min. = 2L + 88 40.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 58
41. Vertical and horizontal section of 2 moving door wings and 2 fixed door wings with beam (standard version) L (min. 1715, max. 6000) PL = (L - 68 - 2X) / 2 X (min. 30) X (min. 30) LTmax = L - 20 22.5 Horizontal section Vertical section...
Page 59
42. Vertical and horizontal section of 2 moving door wings and 2 fixed door wings (french version) Valor only (not Rex-S) L (min. 1700, max. 6600) PL = (L - 98) / 2 LT min. = L + 70 22.5 Horizontal section Vertical section IP2275 - 2017-04-30...
Page 60
43. Vertical and horizontal section of 2 moving door wings and 2 fixed door wings with beam (french version) Valor only (not Rex-S) L (min. 1700, max. 6600) PL = (L - 68 - 2X) / 2 X (min. 30) X (min.
Page 61
44. Vertical and horizontal section of 2 moving door wings and 2 fixed door wings with overlight (standard version) L (min. 1715, max. 6000) PL = (L - 68 - 2X) / 2 X (min. 30) X (min. 30) LTmax = L - 20 22.5 Horizontal section Vertical section...
Page 62
45. Vertical and horizontal section of 2 moving door wings and 2 fixed door wings with overlight (french version) Valor only (not Rex-S) L (min. 1700, max. 6600) PL = (L - 68 - 2X) / 2 X (min. 30) X (min.
Page 105
48. Details of additional dimensions VALOR IP2275 - 2017-04-30...
Page 106
49. Instructions for assembling and installing (list of types) A1 (left) A1 (right) A2 (left) A2 (right) A3 (left) A3 (right) IP2275 - 2017-04-30...
Page 107
49. Instructions for door assembling and installing Mobile wing Fix wing V2091 V2086 V2089 V2095 V2094 V2085 KAM30 V2090 RGR2469 KAF30 RGR2140 RGR2141 V2089 V2087 V2094 RGR2469 V2096 RGR2140 V2087 RGR2141 VSP14 VGR2098 IP2275 - 2017-04-30...
Page 108
49. Instructions for assembling and installing (doors type A1/B1) Frame post fixing Floor guide fixing Wing positioning Post closing fixing Simplified beam fixing Automation climbing Operator fixing IP2275 - 2017-04-30...
Page 109
49. Instructions for assembling and installing (doors type A2/B2) Fixing frame installation Post closing fixing Section Fix wing positioning Support beam fixing End cap Automation climbing IP2275 - 2017-04-30...
Page 110
49. Instructions for assembling and installing (doors type A3/B3) Fixing frame installation Post closing fixing Section Fix wing positioning Floor guide fixing Beam holder positioning Wing lateral side fixing IP2275 - 2017-04-30...
Page 111
49. Instructions for assembling and installing (doors type A3/B3) T100 Automation climbing Operator fixing Beam cover Beam cover fixing IP2275 - 2017-04-30...
Page 112
49. Instructions for assembling and installing T101 Mobile wing bracket fixing Carrier adjustment Belt adjustment Electrolock adjustment IP2275 - 2017-04-30...
Page 113
All the rights concerning this material are the exclusive property of Entrematic Group AB. Although the contents of this publication have been drawn up with the greatest care, Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication. We reserve the right to make changes without prior notice.
Page 114
Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.entrematic.com...
Need help?
Do you have a question about the Ditec PAM30STD and is the answer not in the manual?
Questions and answers