Ground Contact Anti-Static Straps - PSC Falcon 4400 Series Installation Manual

Falcon 4400 series powered vehicle dock
Hide thumbs Also See for Falcon 4400 Series:
Table of Contents

Advertisement

Electrical Considerations

Ground Contact Anti-Static Straps

The recommended method of reducing static buildup is to install ground con-
tacting anti-static straps or conductors to the frame of the forklift (refer to Fig-
ure 3).
Contact your forklift parts provider for availability.
Figure 3. Installing Ground Contact Anti-Static Straps
It is recommended that more than one strap be installed on each vehicle to
help eliminate or reduce the potential for static buildup while the vehicle is in
motion. This will provide an adequate level of redundancy, should one of the
straps become dislodged from the lift.
Ground Contact Anti-Static Straps should be checked at regular intervals to
ensure proper installation or identify need for replacement.
6
Ground Contact
Anti-Static Straps
Falcon
®
4400 Series Powered Vehicle Dock

Advertisement

Table of Contents
loading

Table of Contents