Command Details: Set_Configuration_Data
Category
Extended
Details
Command Code:
Valid for:
Description
If the data segment in the CIP 'Forward_Open' service contains Configuration Data, this will be for-
warded to the host application through this command. If implemented, the host application should eval-
uate the request and return a proper response.
Segmentation is used, see "Message Segmentation" on page 189 for more information. The maximum
total amount of configuration data that will be accepted by the module is 458 bytes.
Note: This command must be implemented in order to support Configuration Data. If not implement-
ed, the CIP 'Forward_Open'-request will be rejected by the module.
Command Details
Field
CmdExt[0]
CmdExt[1]
a
MsgData[0 - 1]
a
MsgData[2 - 3]
MsgData[0... n]
a. MsgData[0 - 1]and MsgData[2 - 3] can both be 0. Normally, the Set_Configuration_Data command is sent to the
application when an I/O connection is setup on the network. Producing connection point and consuming connec-
tion point are available and will be forwarded with the command. But if the configuration data originates from a set
attribute single request or a not matching NULL forward open request, there is no information on the connection
points and 0 (zero) will be forwarded to the application.
Response Details (Success)
Field
CmdExt[0]
CmdExt[1]
Response Details (Error)
Field
CmdExt[0]
CmdExt[1]
MsgData[0]
MsgData[1]
MsgData[2 - 3]
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
11h
Object Instance
Contents
-
Segmentation Control bits
Producing connection point
Consuming connection point Consuming connecition point, requested by the originator.
Data
Contents
00h
00h
Contents
00h
00h
Error code
Extended error code
Index
Notes
(reserved, ignore)
See "Message Segmentation" on page 189
Producing connection point, requested by the originator.
Actual configuration data
Notes
(reserved, set to zero)
(reserved, set to zero)
Notes
(reserved, set to zero)
(reserved, set to zero)
Anybus error code
If the Anybus error code is set to FFh, the extended error
code shall be translated as shown in "Extended Error
Code" on page 168.
If the Extended error code is set to 02h (invalid configura-
tion), this parameter points to the attribute that failed.