Technical Data - Graco VISCON HP Instructions - Parts Manual

High pressure fluid heater, non-hazardous/hazardous location heater
Hide thumbs Also See for VISCON HP:
Table of Contents

Advertisement

Technical Data

Technical Data
The heater can be used in the following environmental conditions: indoor use, 99% maximum relative humidity, pollu-
tion degree 2, installation category II, maximum ambient temperature 140° F (60° C).
Maximum Working Pressure
Voltage / Wattage / Current*
Fluid Passage Area
Fluid Passage Diameter
Fluid Passage Length
Thermometer Range
Wetted Parts
Temperature Operating Range
Weight
*
Main supply fluctuation not to exceed 10%.
100
94.16
90
80
70
60
54.14
50
40
30
20
10
0
0
28
Maximum Temperature Rise vs. Flow Rate
4000 watt VISCON HP heater, Test Fluid: 10w Hydraulic Oil
2300 watt VISCON HP heater, Test Fluid: 10w Hydraulic Oil
NOTE: Line shows continuous operation of 1 heater.
Use additional heaters if necessary.
68.39
57.70
50.68
42.23
39.32
33.18
29.14
24.28
0.5
1
1.5
Flow Rate (GPM)
7250 psi (50 MPa, 500 bar)
See Contents, page 2
2
2
182 in.
(117,419 mm
)
0.435 in. (11.1 mm)
133 in. (3383 mm)
64–250°F (18–121°C)
Stainless Steel
84–219°F (29–104°C)
39 lb. (17.6 Kg)
34.96
30.26
26.64
20.10
17.40
15.32
2
2.5
3
4000W
2300W
3.5
309524V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents