Summary of Contents for Barnstead SUPER-NUOVA HP133420-33
Page 1
SUPER-NUOVA ™ Digital Plates OPERATION MANUAL AND PARTS LIST Model # Voltage Description HP133425 7X7 Hot Plate HP133420-33 220-240 7X7 Hot Plate HP133424 7X7 Hot Plate SP133525 7X7 Stirring Hot Plate SP133520-33 220-240 7X7 Stirring Hot Plate SP133524 7X7 Stirring Hot Plate LT1335X1 •...
Page 2
Table of Contents Safety Information ................................3 Alert Boxes ................................3 Warnings................................3 General Specifications..............................5 Hot Plate Specifications ............................5 Stirring Hot Plate Specifications ..........................5 Heating Specifications ............................6 Stirring Speed Specifications ..........................6 Environmental Conditions............................7 Declaration of Conformity ............................7 Introduction ..................................8 General Usage ..............................8 Unpacking and Installation ............................9 Unpacking................................9 Installation................................9 SUPER-NUOVA Hot Plate Control Panel......................10...
Safety Information Your Barnstead|Thermolyne SUPER-NUOVA Hot Plate or Alert Signals Stirring Hot Plate has been designed with function, relia- bility, and safety in mind. It is your responsibility to install it in conformance with local electrical codes. For safe Warning...
Page 4
AFETY NFORMATION Use appropriate hand and eye protection when handling hazardous chemicals. Gross weight of items placed on top of units should not exceed 25 lbs. (11.3 kg). “Caution: Hot Top. Avoid Contact.” The top plate of the unit can remain hot for some time after use.
ENERAL PECIFICATIONS Heating Specifications Top Plate Surface - Solid Aluminum Temperature range: 1°C - 300°C (34°F - 572°F)* * These plates do not cool. The minimum temperature is 1°C if used in a cold room below 1°C. Heat-up time to within 5°C of maximum temperature (unloaded top plate). 5 minutes Accuracy of the temperature display vs.
-25°C to 65°C 10% to 85% relative humidity Declaration of Conformity (for 220-240 volt, -33 CE models only) Barnstead International hereby declares under its sole responsibility that this product conforms with the tech- nical requirements of the following standards: EMC: EN 61000-3-2...
Introduction Please read all the information in this manual before operat- ing the unit. Your Barnstead|Thermolyne SUPER-NUOVA hot plate or stirring hot plate is a heating and/or stirring plate designed for laboratory procedures requiring precise control of tem- perature and/or stirring speed. Each SUPER-NUOVA model...
If the unit appears to have sustained handling capacity. shipping damage contact the distributor from whom you purchased this product or Barnstead International Do not remove or modify grounded Customer Service at 800-553-0039. Check for stir bar, power plug. Use only properly ground- remote probe and thumbscrew prior to discarding packag- ed outlets to avoid shock hazard.
NPACKING AND NSTALLATION SUPER-NUOVA Hot Plate Control Panel HEAT HEAT POWER POWER CAUTION! UTION! HOT TOP HOT TOP EXTERNAL EXTERNAL PROBE PROBE TIMER TIMER PRESETS PRESETS ADJUST (hours) ™ ™ SUPER-NUOVA SUPER-NUOVA SUPER-NUOVA Stirring Hot Plate Control Panel HEAT HEAT STIR STIR POWER...
NPACKING AND NSTALLATION Control Panel Description CAUTION! HOT TOP Indicator Temperature Display Temperature Set Button Power Button Writable Preset Surface Preset Buttons External Probe Indicator Light Set Indicator Light Knob Timer Timer Indicator Lights Speed Set Button Speed Display Pause Button Pause Indicator Light Set Indicator Light Features...
Principles of Operation Each SUPER-NUOVA unit utilizes the latest microproces- sor technology to deliver the most reliable, accurately controlled, aluminum top digital plate on the market. Your SUPER-NUOVA plate has an electronic, closed-loop feedback control which will accurately maintain tempera- ture setpoints from 1°C through 300°C.
Operation Power Button Warning The SUPER-NUOVA unit has a power button located on Use caution when heating volatile the front control panel. The unit may be powered on by materials; top surface and element pressing the power button or ANY button on the control can reach the “Flash Point panel.
(A 6" or 10" stainless steel general purpose immersion probe [part numbers TC732X1 and TC732X2], or a chemical-resistant 7" Teflon immersion probe [part number TC727X2] are available by contacting Barnstead International, 800-553-0039). The SUPER-NUOVA plate will accept any ungrounded Type K thermocouple probe,...
Page 15
PERATION Controlling Solution Temperature Using External Probe To control the solution temperature plug the included probe or an ungrounded Type K thermocouple probe into the probe receptacle located on the right side of the unit. Be careful to observe the correct polarity of the probe connector when inserting probe.
PERATION Using Preset Programs The SUPER-NUOVA plate features the option of presetting 4 setpoints into its memory. To program a preset, adjust the heat and/or stir features to your desired setpoints. Press and hold one of the presets and the unit will beep indicating those setpoints have been stored in memory.
PERATION If at any time you wish to reset the timer, press the right or left arrow keys until the indicator light corresponds to your desired time. The unit will beep indicating it has been reset. One minute before shutdown, the unit will beep three times and flash the 1 hour light.
PERATION RS232 Output An RS232 port is available on the SUPER-NUOVA to output elapsed time, speed, and temperature data. The data is print- ed once every second when the unit is powered on (displays on). A comma separates each piece of data so that it may easily be imported into a spreadsheet as CSV (Comma Separated Values).
PERATION Using HyperTerminal w/RS232 With HyperTerminal you can store the RS232 output data of a SUPER-NUOVA on a PC. NOTE: Other terminal programs that capture RS232 data can be used as well. In order to follow this procedure, you must have: •...
Page 20
PERATION Select FILE, SAVE AS, and save this setup wherever you would like it to be located (if you would like it on the Desktop, select Desktop) and select SAVE. You will be able to run HyperTerminal with this setup in the future by just double-clicking the icon if you put it on the Desktop.
Service and Calibration Service Menu The Service Menu has many features that will allow a user to customize their unit. A table of the features available in the Service Menu is given below. The features are given in order of their appearance in the Service Menu when rotating the center knob in a clockwise rotation.
ERVICE AND ALIBRATION Over-temperature Set Point - Note For most routines, the POWER key This option is only available for units that have heating can be used to return to a previous functionality. The Over-temperature Set Point is the set menu if desired.
See the “Accessories” section for N.I.S.T. traceable thermometers available from Barnstead International. The bath chosen should be as simi- lar to the user’s typical load as possible. For example, if the load is 150ml of aqueous solution in a 500ml Erlenmeyer flask, then the load during calibration should be the same.
ERVICE AND ALIBRATION System Method of Calibration Select an independent temperature probe to be placed in the load, along with the unit tempera- ture probe before continuing with calibration. Select the load to be calibrated, and place on top of the hot plate. Place a stir bar in the mix- ture if stirring is desired and available on the unit being calibrated.
ERVICE AND ALIBRATION stirring capability then skip to the next step. The SET indicator under the STIR display will be lit, and the displays will show the stirring control set point. The speed may be adjusted by using the center knob. The adjustable range is 50 – 999, and also OFF (zero).
ERVICE AND ALIBRATION holding the POWER key. After about 3 seconds a single beep will be heard and you may remove your finger from the POWER key. The display will change to OSP. Rotate the center knob dial one position clock- wise and the display will read CAL.
ERVICE AND ALIBRATION Hot Top Warning System is indicating a hot sur- face), enter the Service Menu by pressing and holding the POWER key. After about 3 seconds a single beep will be heard and you may remove your finger from the POWER key. The display will change to OSP.
ERVICE AND ALIBRATION accept, and the display will change to H (Heating off), H S (Heating and Stirring Off), or S (Stirring Off). Rotate the center knob to change the display to the method of choice and press the SET key under either display again. The unit will return to the previous menu.
ERVICE AND ALIBRATION Probe Response - Pr This feature is available for units with heating functionality and is only applicable when using a probe. The purpose of this feature is to select the minimum time required for a temperature change to be detected before signaling a Probe Out of Solution error (E03).
ERVICE AND ALIBRATION of OSP. Selection of UL would allow the set point to be unlimited and would not be affected by OSP setting. To modify/view the Set Point Limit follow the instructions given below: Plug the unit into the appropriate power, but do not turn it on (displays should be blank, unless Hot Top Warning System is indicating a hot sur- face), enter the Service Menu by pressing and...
ERVICE AND ALIBRATION Rotate the center knob until the display reads Err. Press the SET key under either display to accept, and the display will change to CLr (re- enable all disabled errors). Rotate the center knob to change the display to the error number of choice and press the SET key under either display again.
ERVICE AND ALIBRATION The unit has now been returned to the factory default settings. The unit will return to the previ- ous menu. Select another feature to change, or press the POWER key again to return to the off mode. Model Selection - SEL This feature is available for all units to select the type and size, but should only be used by the factory.
ERVICE AND ALIBRATION Flash Upgrade - FLS This feature is available for all units and is designed to allow a firmware upgrade via RS232 port to be applied without exchanging controls. NOTE: Special software and an RS232 cable are required to complete this proce- dure.
Troubleshooting Error Codes Errors E01 through E07 are heating errors. Error Handler will lock out heating functions if heating error is detected. Stirring functionality is unaffected. If the condition that caused the error is no longer present, pressing the POWER button or unplugging the unit will clear Errors E01-E07. y t i .
Page 35
ROUBLESHOOTING Errors E11 and E12 are stirring errors. Error Handler will lock out stirring functions if stirring error is detected. To avoid boil over, the unit will cease heating (the user can restart heating if desired). Pressing the POWER button or unplugging the unit will clear Error E12. Unplugging the unit will clear Error E11. y t i .
To insure your safety and for proper operation, the aluminum top plates for hot plates and stir plates are only sold as complete assemblies. This assembly includes the aluminum top, element, thermocouple, insulation, baffle plate, and 2 aluminum top holders. Barnstead recommends not replacing individual components of the top plate.
12” Aluminum Rod 7078 Large Clamp 7079 Small Clamp (up to 1/2”) RS232 cable WHX18 NOTE: Thermometers are N.I.S.T. traceable, however, they do not come with N.I.S.T. certificates. To obtain a certificate before ordering, call Barnstead International Customer Service at 1-800-553-0039.
All parts listed herein may be ordered from the Barnstead International dealer from whom you purchased this unit or can be obtained promptly from the factory. When service or replacement parts are needed we ask that you check first with your dealer.
BARNSTEAD’s warranty provided hereunder shall be null and void and without further force or effect if there is any (i) repair made to the product by a party other than BARNSTEAD or its duly authorized service repre- sentative, (ii) misuse (including use inconsistent with written operating instructions for the product), mishan- dling, contamination, overheating, modification or alteration of the product by any customer or third party or (iii) use of replacement parts that are obtained from a party who is not an authorized dealer of BARNSTEAD.