Once the reset button is pressed over 5s red NOTIFICATION LED starts blinking again
o
but faster and green CONNECTION LED is lit
Release the reset button before 10s is elapsed to enter to the recovery mode. This mode
o
can be entered once 5-10s is elapsed from starting to press the reset button.
Factory reset
Once the reset button is pressed over 10s red NOTIFICATION LED starts blinking even
o
faster and green RFID LED is lit
Release the reset button before 15s is elapsed to set reader to factory defaults. This
o
mode can be entered once 10-15s is elapsed from starting to press the reset button.
* Recovery mode can be used to repair the reader
NOTE! Pressing the reset button >15s will perform a normal boot in case one keeps pressing the

BUZZER

Nordic ID Sampo S2 includes a buzzer for sound indications. The buzzer can be controlled via SW.
CAPACITIVE SENSOR
Nordic ID Sampo S2 includes a capacitive sensor for triggering reading. The capacitive sensor can be
controlled via SW. Location of the capacitive sensor can be found from Figure 3. Diameter of the
capacitive sensor is 27mm.
Figure 3 Location of capacitive sensor
Nordic ID Group
| Salo IoT Center | Joensuunkatu 7 | FI-24100 Salo |Finland
Office +358 2 727 7700 | Fax + 358 2 727 7720 | info@nordicid.com
reset button by mistake.