Hayward HeatPro HP50TA Troubleshooting Manual page 26

Hayward/summit heat pump
Table of Contents

Advertisement

Summit/EnergyTherm/HeatMaster/EasyTemp Setup Menu
PRESS AND HOLD
SET BUTTON
5 SECONDS
Release SET button and press up arrow until 50 appears
Loc
This will unlock settings menu. Press SET again
AFF
P_S-POOL_SPA
Set high pool limit
61-95 F
PHL
using up or down arrows
Set high spa limit
61-104 F
SHL
using up or down arrows
Calibrate water temperature sensor
CAL
+ 5 F
Calibrate coil temperature sensor
+ 5 F
CAD
OR
N
P_S
Press down arrow for
normal operation
Calibrate temperature differential
DB1
0.2-2 F
(dead band between on and off)
Not used
HGD
Sets heat pump to operate only in
pool or spa mode , or in both modes
E
Press up arrow for
external controller
Combination Key Functions
Set + Dn
Bypass 3 minute time delay
Set + Up
Display coil temperature
Set+Up+Dn
Reset factory defaults

Advertisement