Scale Menu Definitions - CAMBRIDGE CSW-15AT Installation, Setup And Operation Instructions

Wireless remote control digital weight indicator
Table of Contents

Advertisement

Enter Calibration / Setup mode by Pressing and holding the
event counter is displayed, then release. Immediately after
sec.) TARE, lb/kg, GRS/NET, and PRINT/ENTER.
to enter the scale menu. Press the right arrow key to enter each sub menu.
-P xxx, C xxx are event counters that will increment each time one or more changes are made
to the Scale or Calibration Parameters.
S1
Ntep
(Ntep): Maximum divisions limited to 5000 negative
Angle: Enables angle correction for Legal For Trade Lift truck scales.
S2
Capacity
S3
Count By
S4
Overload
S5
Zero Limit
S6
Filter
S7
Motion Band 1 to 99 divisions. The weight display must be stable within the selected
S8
Motion Delay 0 to 99 updates. The weight display must be within the motion band for the
S9
Motion
Display
S10 Zero Band

2.2 Scale Menu Definitions:

Scale negative message is displayed if the gross weight goes more
than 10 divisions below zero. If a capacity and count by of more
than 5000 divisions is selected
be returned to S2 to select a new capacity and count by.
No: 20,000 maximum division limits and no scale negative tests.
1 to 950,000 pounds. 5000 (Default)
.0001, .001, .01, .1, (1), 10, 100
.0002, .002, .02, .2, 2, 20, 200
. 0005, .005, .05, .5, 5, 50, 500
(105%) of the scale capacity or user entered value.
(100%) or 1.9% of scale capacity.
0 to 7, Where 0 is the fastest response and least filtering and 7 is the lowest
response or most filtering. 3 (Default)
number of divisions for the motion indicator to be turned off. 2 (Default)
selected number of updates in order to turn off the motion indicator. 4
(Default)
(Normal): When the scale is in motion the motion LED will aluminate.
Blank: When the scale is in motion the display will be blanked out.
Dashes: When the scale is in motion the display will show all dashes.
1 to 99 divisions. The weight display must return to zero within the selected
number of divisions to be considered zero. 2 (Default)
GRS/NET
CodE
is displayed, enter in sequence (within 5
ScAlE
will be displayed. Press the down arrow key
Err d
will be displayed, then you will
8
key until Parameter (Pxxx)

Advertisement

Table of Contents
loading