Scale Menu Definitions - CAMBRIDGE CSW-10AT Installation And Operaion Manual

Digital weight indicator
Table of Contents

Advertisement

NTEP
S1
S2 Capacity
S3 Count By
S4 Over load
S5 Zero Limit
S6 Filter
S7 Motion Band
S8 Motion Delay
S9 Motion (Normal): When the scale is in motion the motion LED will
Display
S10 Zero Band
CAMBRIDGE SCALE WORKS, INC.

2.3 Scale Menu Definitions:

(Ntep): Maximum divisions limited to 5,000.
Scale negative message is displayed if the gross weight
goes more than 10 divisions below zero. If a capacity and
count by of more than 5,000 divisions is selected
will be displayed and you will be returned to
select a new capacity or count by.
Angle: Enables angle correction for Legal For Trade
lift truck scales.
No: 20,000 maximum division limits and no scale negative tests.
1 to 950,000 pounds (5,000).
.001, .01, .1, (1), 10, 100,
.002, .02, .2, 2, 20, 200
.005, .05, .5, 5, 50, 500
(105%) of scale capacity or user entered value.
(100%) or 1.9% of scale capacity.
0 - 7 (3) 0 is the fastest response or least filtering and 7 is
the slowest response or most filtering
1 to 99 divisions (2) the weight display must be
stable within the selected number of division
for the motion indicator to be turned off.
0 to 99 updates (4) the weight display must be
within the motion band for the selected number
of updates for the motion indicator to be turned off.
light.
Blank: When the scale is in motion the display will be
blanked out.
Dashes: When the scale is in motion the display will show
all Dashes.
1 to 99 divisions (2) the weight display must return
to Zero within the selected number of divisions to
to be considered Zero.
7
ERR d
to
S2
MANUAL P/N 5999-1014-01