CAMBRIDGE CSW-15AT Installation, Setup And Operation Instructions

Wireless remote control digital weight indicator

Advertisement

Quick Links

1

Advertisement

Table of Contents
loading

Summary of Contents for CAMBRIDGE CSW-15AT

  • Page 2 TABLE OF CONTENTS Meter connections ------------------------------------------------------------------ 3 1.0 Operation ------------------------------------------------------------------------ 4 1.1 Key Functions ---------------------------------------------------------- 4 1.2 Error Messages --------------------------------------------------------- 4 1.3 Numeric Entries -------------------------------------------------------- 5 1.4 Setup Parameters ------------------------------------------------------- 5 2.0 Scale Procedure ----------------------------------------------------------------- 6 2.1 Software Navigation Flowchart -------------------------------------- 6 - 7 2.2 Scale Menu Definitions ----------------------------------------------- 8 - 9 3.0 Calibration Procedure --------------------------------------------------------- 10 3.1 Calibration Menu Definitions ---------------------------------------- 10...
  • Page 3: Meter Connections

    METER CONNECTIONS To connect power via AC wall adapter cable to the CSW-15AT meter. First make sure the On/Off switch on the rear of the meter is in the off position. Connect the wall adapter to your 110VAC outlet. Next, connect the other end of the cable to the connector on the rear of the indicator.
  • Page 4: Operation

    1.0 OPERATION 1.1 Key Functions: ZERO Brings the scale to a zero balance reading. If the ZERO is pressed and held for 5 seconds the Calibration zero value will be displayed. GRS/NET Toggles the display between Gross weight and Net weight. This key is also used to enter Setup &...
  • Page 5: Numeric Entries

    1.3 Numeric Entries: Once you have entered Setup and Calibration mode, (as described on the previous page) some entries may require entering a numeric value. To enter a numeric value: 1. Press and release the lb/kg key to move into the desired menu field. 2.
  • Page 6: Scale Procedure

    2.0 SCALE PROCEDURE 2.1 Software Navigation Flowchart: SCALE CALIBRATION RS-232 TEST ( Ntep) Show Raw 1200,8,N,1- Software Counts then 19200,8,N,1? Version Ntep Zero & clear Baud Rate Version Angle “0” (Gross,Tare,Net) 1 to Illuminate Show Raw Weight only 999,999 Segments Counts then Capacity Output...
  • Page 7: Software Navigation Flowchart

    1 to 99 2.1 Software Navigation Flowchart: Divisions Zero Band 0 - 99 Updates Zero Delay 1 - 99 Divisions Zero Tracking 1 - 99 ¼ sec increments Tracking Delay lb/kg (lb/kg) 1 – 99 ID’s Used in RF Scale ID Link 0 –...
  • Page 8: Scale Menu Definitions

    2.2 Scale Menu Definitions: Enter Calibration / Setup mode by Pressing and holding the GRS/NET key until Parameter (Pxxx) event counter is displayed, then release. Immediately after CodE is displayed, enter in sequence (within 5 sec.) TARE, lb/kg, GRS/NET, and PRINT/ENTER. ScAlE will be displayed.
  • Page 9: Scale Menu Definitions

    2.2 Scale Menu Definitions Continued: S11 Zero Delay 0 to 99 updates. The weight display must be within the zero band for the selected number of updates to be considered zero. 4 (Default) S12 Zero 0.5 divisions. Tracking 1 division. (Default) 3 division Press the right arrow key to enter.
  • Page 10: Calibration Procedure

    3.0 CALIBRATION PROCEDURE 3.1 Calibration Menu Definitions: Zero All Raw counts, (Pitch and Roll if in angle mode) will be displayed. When ZERO is pressed an analog zero is done and all calibration span points will be cleared. If the indicator is in angle mode the Pitch and Roll offsets will also be Zeroed.
  • Page 11: Calibration

    3.2 Calibration: Press and hold the GRS/NET key, as described previously in section 1.4. ScAlE will be displayed. Press the lb/kg key to move right until CalIb is displayed. Press the GRS/NET key to move down, will be displayed. Press the lb/kg key to move right, The raw counts will be displayed.
  • Page 12: Communications Setup

    4.0 COMMUNICATIONS SETUP 4.1 Communications Menu Definitions: Baud Rate 1200 to 115200 baud (9600) Default.8, n, 1 Output Gross, Tare, Net (Default) Format “CR, LF, CR, LF [32 bytes of 2Eh], CR, LF, CR, LF, Gross (lb or kg), :, six ASCII characters [indicated weight], CR, LF, Tare (lb or kg), sp, :, six ASCII characters [indicated weight], CR, LF, CR, LF, CR, LF, CR, LF”...
  • Page 13: Testing Procedure

    5.0 TESTING PROCEDURES 5.1 Testing Menu Definitions: Software Displays the software version. Press PRINT/ENTER to exit. Version Display Flashes all display segments then all indicating Enunciators. Press PRINT/ENTER to exit. Keys Press the ZERO key, b1 will be displayed. Press the GRS/NET key, b2 will be displayed.
  • Page 14: Warranty

    CAMBRIDGE the equipment has not been mechanically, environmentally, or electrically abused. This warranty is limited, at the option of CAMBRIDGE, to repair, replace or an appropriate credit adjustment, not to exceed the original equipment sale price paid to CAMBRIDGE. CAMBRIDGE assumes no liability in connection with the sales of its products beyond that stated above.