Conversion Table - JVL FBG10 User Manual

Field bus gateway
Table of Contents

Advertisement

5.1
FBG10 contains a convertion table which is shown below.
In this conversion indicates:
INDEX:
The value which master writes as output data in COMMAND. See section 3.6, "Descrip-
tion of Output Data", page 21.
COMMAND NAME:
The ASCII-string, which the command is converted to on RS 232.
QUESTION ALLOWED, COMMAND ALLOWED:
Question allowed indicates if it is legal to request on the content of the motor controller
register. Command allowed indicates if it is legal to allocate a value to the motor control-
ler register. See section 4.2, "Command Description", page 29.
FORMAT:
Indicates default format for the motor controller register.
LONGINT = Signed integer, 32 bit.
WORD = Unsigned integer, 16 bit.
INTEGER = Signed integer, 16 bit.
FIXED = Fixed point * 1000. Se section 4.3.9.
NONE = No data in connection with this command.
Note: By rewriting of the table, (is made by JVL according to customer specifications),
FBG10 can be adapted to other products with another set of commands.
Tabel.
Question
allowed
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
36
JVL Industri Elektronik A/S — User Manual — Field Bus Gateway FBG-10

Conversion Table

Command
Format
allowed
(default)
YES
LONGINT
YES
WORD
YES
INTEGER
YES
LONGINT
YES
LONGINT
YES
LONGINT
YES
WORD
YES
WORD
YES
LONGINT
YES
LONGINT
YES
WORD
YES
LONGINT
Command
Index
name
R00..R99
0..99
RB00..RB99
100..199
RI00..RI99
200..299
XA00..XA63
300..363
XP00..XP63
364..427
XR00..XR63
428..491
XV00..XV63
492..555
CB00..CB63
556..619
RX00..RX31
620..650
AC
651
ACH
652
ACP
653