Taylex verifying their successful training in the installation and maintenance of Taylex equipment. Taylex has an ongoing commitment to the industry and is a member of the Wastewater Practitioners Association. It has ISO:9000 Certification and its products are approved by all State Authorities and comply with all relevant Australian Standards.
Page 6
AN EXPLANATION OF HOW YOUR TAYLEX ABS OPERATES The Four Stages to a Taylex Treatment System Primary and Secondary Anaerobic Digestion All Household Waste Enters and Sedimentation The System Chambers Clear Recycled Water for Irrigation Aerobic Biological Disinfection Digestion Occurs in the...
The Taylex tank is fitted with an air blower that takes fresh air and introduces it to the water through an aerator disc. Some of the gaseous oxygen in the air dissolves in the water as it bubbles up to the top and this gives the water a higher than normal dissolved oxygen content.
Page 11
8. HOW TO LOOK AFTER YOUR TAYLEX HSTP • Never turn the electricity supply to the plant OFF*. Turning the supply OFF will: Stop the air supply and kill the bacteria. Flood the system Disable the alarm system Cause back-up in your sewer line from the house The plant will smell, the equipment may be damaged and you will be in contravention of your “Permit to Use”...
Systems may only be serviced by appropriately trained and licensed Wastewater Service personnel. There are better reasons for servicing your Taylex HSTP than just complying with the law. Your service person is trained to monitor your system; they can detect problems often before they become a hazard.
10. WARRANTY Every Taylex Advanced Blower System is covered by a full manufacturers warranty. There is a 15 year warranty on the pre-cast concrete or plastic tank. There is also a 3 year* warranty on all electrical and mechanical components including the irrigation pump (a 12 month standard warranty and a further 24 months extended warranty is available when you purchase your 2nd and 3rd year of service calls with a Taylex Approved Service Agent).
Page 14
11. OPERATING INSTRUCTIONS FOR CONTROLLER Introduction The Taylex ABS Control Panel has a number of features that are explained in this section. The basic purpose of the Control Panel is to activate and control the functioning of the Treatment Plant’s air pump and to register an alarm when it detects a fault in the system.
Page 15
General Your Taylex ABS is designed to operate automatically and its operation will usually be event free. The Control Panel provides visual and audible indictors of both normal operating conditions and fault conditions. The illustration on the previous page provides description markers that correspond with the following description of their operation.
Page 16
Normal Operation at Start-up Every time that power is switched on to your Taylex ABS Control Panel, the display (B) will count down from 9 to 1. The audible alarm will sound in unison with the numeric progression. This is a TEST MODE, at the completion of which, the display will show a 0 rotating to indicate that the system has tested out correctly.