Activating The Dry Charge Battery (If Applicable) - Miller Big Blue 800 Owner's Manual

Engine driven welding generator
Table of Contents

Advertisement

5-7. Activating The Dry Charge Battery (If Applicable)

2
1
Tools Needed:
5-8. Connecting The Battery
Tools Needed:
1/2 in.
3
4
+
+
!
Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
1
Vent Caps
2
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
3
Well
Fill each cell with electrolyte to
bottom of well (maximum).
!
Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
4
Battery Charger
!
Read and follow all instruc-
tions supplied with battery
charger.
5
5 Amperes For 30 Minutes
Charge Time
6
30 Amperes For 12 Minutes
5
Charge Time
Charge battery. Disconnect charg-
ing cables and install battery.
.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
5 A
6
30 A
!
Connect negative (−) battery
cable last
.
Reinstall cover after connecting
battery.
802 168-E / Ref. 202 705 / 802 313 / S-0756-C
drybatt 12008−01 − S-0886
OM-244 023 Page 25