Section 8 − Engine/Generator Maintenance - Miller Big Blue 800 Owner's Manual

Engine driven welding generator
Table of Contents

Advertisement

SECTION 8 − ENGINE/GENERATOR MAINTENANCE
8-1. Routine Maintenance
n = Check
* To be done by Factory Authorized Service Agent
Every
FUEL
8
WATER
Hours
n Fuel/Water Separator
Every
50
Hours
~ Weld Terminals
Every
100
Hours
~ Battery Terminals
Every
250
Hours
l Unreadable Labels
Every
500
Hours
nl Weld Cables
Every
1000
Hours
Z Fuel Filter
n~ Slip Rings*
nl Brushes*
Every
3000
Hours
~ Injectors*
Every
6000
Hours
or 5
Years
nl Engine Timing Belt
OM-244 023 Page 38
Z = Change
~ = Clean
n Fuel Level
n Air Cleaner Hoses
1/2 in.
(13 mm)
n Fan Belt Tension
Z Oil
Z Oil Filter
OR
~ Inside Unit
!
Stop engine before maintaining.
.
See Engine Manual and Maintenance Label
Recycle engine
for important start-up, service, and storage
fluids.
information. Service engine more often if
used in severe conditions.
l = Replace
Cold High
Warm High
Cold Low
Warm Low
n Oil Level
~ Oil, Fuel Spills
n Air Cleaner Element
~ Cooling System
n~Spark Arrestor
NOTICE − Change engine
oil and filter after initial 50 to
75 hours of use.
SLUDGE
nValve Clearance*
~ Drain Sludge
Reference
Section
5-10, 8-8
Section 8-4
Engine
Manual,
Section 8-5
Section 8-8,
FUEL
8-6 and
Engine
Manual

Hide quick links: