Activating The Dry Charge Battery (If Applicable) - Miller Trailblazer 302 Diesel Owner's Manual

Hide thumbs Also See for Trailblazer 302 Diesel:
Table of Contents

Advertisement

5-4. Activating The Dry Charge Battery (If Applicable)

2
1
Tools Needed:
5-5. Connecting the Battery
Tools Needed:
1/2 in
3
5 A For 30 Minutes
OR
+
30 A For 12 Minutes
4
Y Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
1
Vent Caps
2
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
3
Well
Fill each cell with electrolyte to
bottom of well (maximum).
Y Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
4
Battery Charger
Y Read and follow all instruc-
tions supplied with battery
charger.
Charge battery for 12 minutes at 30
amperes or 30 minutes at 5 am-
peres. Disconnect charging cables
and install battery.
.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
drybatt1 6/05 − S-0886
Y Connect negative (−)
cable last.
+
804 197-A / Ref 216 171 / Ref. S-0756-D
OM-217 454 Page 13