Specifications - Greenlee H6510A Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Identification
3
1
2
1. Trigger
2. Quick-Change Chuck *
3. Drive Shank *
4. Motor Cap
5. Serial Number
6. Directional Spool
7. Super Spool™ *
8. Tank Port
9. Pressure Port
10. Variable Torque Output Screw *
or Non-Adjustable Torque Output Plug *
*This feature is not available on all models.
Greenlee / A Textron Company
4
5
6
10
9
8

Specifications

Impact Wrench
Type of Hydraulic System ........................ Open-Center or
Hydraulic Ports
Pressure ...............................3/4–16 SAE O-Ring Boss
Tank ......................................3/4–16 SAE O-Ring Boss
Output @ 22.7 l/min (6 gpm)
RPM (No Load) ..................................................... 2700
Torque ......................................... 1900 Nm (1400 ft-lb)
Drive Size .............................................3/4" Square Drive
Sound Power Level ...............................................85 Lwa
Mass/Weight ............................................. 6.4 kg (14.1 lb)
Length .......................................................267 cm (10.5")
Width ..........................................................95 mm (3.75")
Height .......................................................248 mm (9.75")
Hydraulic Power Source
Do not exceed the following hydraulic power source
maximums:
• Hydraulic flow: 45.4 l/min (12 gpm)
• Pressure relief: 138 bar (2000 psi)
• Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Type of Hydraulic System ........................ Open-Center or
Flow
Minimum ......................................... 15.1 l/min (4 gpm)
Recommended ................................ 22.7 l/min (6 gpm)
Maximum ...................................... 45.4 l/min (12 gpm)
Filtration ............................................ 10 Micron (Nominal)
Pressure Relief Setting ........................ 138 bar (2000 psi)
Back Pressure (maximum*) .................. 13.8 bar (200 psi)
* 13.8 bar (200 psi) is the maximum agreed standard back pressure
for the HTMA (Hydraulic Tool Manufacturers Association).
Greenlee Utility tool will operate satisfactorily at this standard.
1. Maximum hydraulic fluid temperature must not
exceed 60 °C (140 °F). A sufficient oil cooling
capacity is needed to limit the hydraulic fluid
temperature.
2. Hydraulic flow must not exceed 45.4 l/min (12 gpm).
Install a flow meter in the return line to measure the
rate of hydraulic flow before using the tool.
5
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
Impact Wrench
Closed-Center
Closed-Center

Advertisement

Table of Contents
loading

Table of Contents