AXIS Q8685-E PTZ Network Camera
NO
NO TICE
NO
TICE
TICE
• Use cables that keep within the specified cable area
• Select cables in compliance with your local regulations
• Make sure all cable holes are properly sealed
• Use cable gaskets or cable glands that match both the cable hole and the cable area
For information about accessories, such as cable gaskets and cable glands that allow for other
cable areas, see www.axis.com
Operating conditions
This Axis product is intended for indoor and outdoor use.
Temperature
Normal: -50 °C to 55 °C (-58 °F to 131 °F)
Maximum (intermittent): 65 °C (149 °F)
Cold start: -40 °C to 55 °C (-40 °F to 131 °F)
Power consumption
Typical consumption
16 W
Important
When using the 22 m (72 ft) AXIS Cable 24 V DC/24–240 V AC, a power supply capable of
delivering 400 W is required to compensate for the power loss in the cable.
Humidity
10–100% RH (non-condensing)
Max consumption
204 W