I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection,
event triggering, and alarm notifications. In addition to the 0 V DC reference point and power (DC
output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for
example PIR sensors, door/window contacts, and glass break detectors.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can
be activated by the VAPIX® Application Programming Interface or in the product's webpage.
A digital light sensor - For receiving a value of the ambient light intensity from an external light
sensor. This is used to control the product's day and night functionality.
6-pin configurable terminal block
Function
Pin
1
DC ground
2
DC output
3–
Configurable
6
(Input or
Output)
Example
AXIS Q8685-E PTZ Network Camera
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate.
Digital output – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. If used
with an inductive load, e.g., a relay, connect a
diode in parallel with the load, to protect against
voltage transients.
27
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC,
open drain, 100 mA